DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

1 Install and Connect Cabinets

 

Fiber Optic Interconnect Cabling

Page 1-31

 

 

CSS-Connected System with 1 Switch Node

Standard-Reliability

Figure 1-11 shows typical fiber optic cabling between cabinets. The cable between the EI and SNI on the PPN is a pre-installed metallic cable (H600-278).

1.If no running list is available, use the outer slots first in alternating order. Connect the first 2 SNI slots to 3 and 20 (the leftmost and rightmost of the unused slots). Next, use 4 and 19, and so forth.

2.Add links to the EPNs in alternating order (20, 3, 19, 4, 18, 5, and so forth).

Figure Notes

 

 

1.

Cabinet 1 (PPN with 1 Switch Node)

3.

H600-278 Metallic Cable

2.

Cabinet 2 through 16 (EPN)

4.

To other EPNs

Figure 1-11. Standard Reliability CSS-Connected Release 6r with 1 Switch

Node