DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

6Test Telephones and Other Equipment

Test Terminating Trunk Transmission

Page 6-6

Test Terminating Trunk Transmission

The Terminating Trunk Transmission Test provides for extension number access to 3 tone sequences that can be used for trunk transmission testing from the distant end of the trunks.

The 3 test types must have extension numbers assigned on the system-parameters maintenance form:

Test Type 100:_______

Test Type 102:_______

Test Type 105:_______

Test type 100 provides:

5.5 Seconds of 1004 Hz tone at 0 dB

Quiet until disconnect; disconnect is forced after 1 minute

Test Type 102 provides:

9 Seconds of 1004 Hz tone at 0 dB

1 Second of silence

Cycle is repeated until disconnect, which is forced after 24 hours

Test Type 105 provides:

9 Seconds of 1004 Hz tone at -16 dB

1 Second of silence

9 Seconds of 404 Hz tone at -16 dB

1 Second of silence

9 Seconds of 2804 Hz tone at -16 dB

30 Seconds of silence

0.5 Seconds of test progress tone (2225 Hz)

Approximately 5 seconds of silence

Forced disconnect

Page 313
Image 313