DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

BOption Switch Settings

 

External Modem Option Settings

Page B-4

 

Table B-1. Modem Fields — Continued

 

 

 

 

 

 

 

 

Modem

 

 

 

 

 

 

 

 

Connection

Description

 

 

 

 

 

 

 

Dial

This field has a default of “D” in a field 3 characters long. This field

 

 

Command

denotes the dialing command of the modem. This is a standard

 

 

 

 

command. This field is not case sensitive. Default is upper case.

 

 

 

 

 

 

No Answer

Most external modems provide a timer that abandons any outbound data

 

 

Time-Out

call after a predetermined interval. Some modems disable this timer,

 

 

 

allowing an outbound call to ring indefinitely. Paradyne does not provide

 

 

 

this capability because it is undesirable to have an outbound call attempt

 

 

 

to ring indefinitely. Therefore, the initialization string must contain the

 

 

 

following ASCII string to set the “No-Answer Timer” to the maximum value:

 

 

 

S7=255. The internal modem must have this parameter disabled or set to

 

 

 

at least 255 seconds. This is a non-administrable parameter.

 

 

 

 

For the modem connection, this parameter is the first initialization string to

 

 

 

be transmitted to the modem. This field is visible on the administration

 

 

 

form in display mode only. The new field is set to S7=255. This hardcoded

 

 

 

constant can be overridden for type approval applications, specifically in

 

 

 

the United Kingdom and other Western European nations, by the use of

 

 

 

the “Misc. Init. Param:” field. (S7=255)

 

 

 

 

 

 

 

 

 

 

 

 

Continued on next page

Page 339
Image 339
Lucent Technologies Release 6 manual External Modem Option Settings B-4