DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Add CallVisor ASAI

Page 5-118

Save Translations

1.If the system is high or critical reliability, enter status system 1 and press Enter to verify that the system is in the “active/standby” mode.

2.Enter save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card or tape.

3.If the system contains a TN750 Announcement circuit pack, enter display announcements and press Enter.

If administered recorded announcements are listed, enter list configuration software-versionand press Enter. Check Page 2 of this form to see when the announcements were last saved. To save the announcements, enter save announcements and press Enter.

Power Down System

If the packet bus is being added:

1.At the PPN, set the main circuit breaker to OFF.

2.At each EPN, set the main circuit breaker to OFF.

Add Circuit Packs

1.Determine port assignment of circuit packs to be added.

2.Install the appropriate circuit pack in assigned cabinet slot (as required). For example:

Port Number 3

B

02

01

Cabinet

Carrier

Slot

Circuit

(Port Network)

 

 

 

The TN748C or TN744 Call Classifier circuit pack is required. The TN744 is required for those customers who desire switch call classification.

A vacant port is required on a TN556 ISDN—BRI circuit pack.

3.A Packet Bus is required with CallVisor ASAI. If the system is not equipped with a Packet Bus, see “ Add Packet Bus to R6si” earlier in this chapter.

Page 269
Image 269
Lucent Technologies Release 6 manual Save Translations, Port Number