DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
1 Install and Connect Cabinets |
|
Fiber Optic Interconnect Cabling | Page |
|
|
Critical Reliability
Figure 1-13 shows typical fiber optic cabling between cabinets. The cable between port slots 1 and 2 on each switch node is a metallic cable (H600-278).
1.Connect the 2 groups of 1 to 15 cables between the PPN and each EPN in an alternating port slot order: 20, 3; 19, 4; 18, 5; and so forth.
Figure Notes
1.Cabinet 1 (PPN with 1 Duplex Switch Node)
2.Cabinet 2 through 16 (EPN)
3.
4.To other EPNs
Figure 1-13. Critical-Reliability CSS-Connected with 1 Switch Node
2.Both connections from each EPN must go to the same slot number. For example: EPN cabinet 2, 2A1 to 1E3 and cabinet 2, 2B2 to 1D3.