Lucent Technologies Release 6 manual T1 Installations Only

Models: Release 6

1 453
Download 453 pages 12.94 Kb
Page 131
Image 131

DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

3Install Management Terminal and Activate System

Administer Fiber Links (Release 6r Only)

Page 3-28

T1 Installations Only

a. The Framing Mode: field is display only and shows the hardware setting.

b. The DS1CONV-1 Line Compensation: and the DS1CONV-2 Line Compensation: fields are display only and show the hardware setting.

c. In the Facility A Circuit ID: field, enter an optional facility name that is unique to each facility (up to 40 alphanumeric characters). Press Enter.

d. A display similar to the following appears after the fiber link administration is completed:

RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED.

E1 Installations Only

a.Enter y or n in the CRC? field. The “CRC” means Cyclic Redundancy Check. This is an error detection algorithm.

b. The Line Termination: field is display only. A 75 (75 Ohms) or 120 (120 Ohms) typically displays.

c. In the Facility A Circuit ID: field, enter an optional facility name that is unique to each facility (up to 40 alphanumeric characters). Press Enter.

d. A display similar to the following appears after the fiber link administration is completed:

RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED.

All Installations

1.When the system reset is finished, enter the status port-network 2 command. The Port Network Status screen appears. Verify that PNC Active is “up” and that the Service State is “in.”

2.A Span LED, on the front of the DS1 Converter circuit pack, must be on for each active facility administered. For example, if Facility A and Facility B are administered, then the top 2 Span LEDs on the circuit pack must be on (yellow). The yellow LEDs are on only if no problems were encountered during the administration of hardware. Span LEDs associated with non-administered facilities (C and D, in this example) should be off.

3.Perform a test call, if desired.

Page 131
Image 131