DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

BRI Terminating Resistor

Page 5-60

Figure 5-25 shows the wiring connections for the 110RA1-12 terminal block. The TN556 Basic Rate Interface (BRI) switch port is terminated to bottom row C.

1

10

11

12

6

2

8

7

T R T1 R1

 

3

9

 

 

4

 

5

Figure Notes

 

 

1.

Part of Terminating Resistor Block

7.

Basic Multi-point Option

2.

White or Purple Field

8.

2-Pair Cross-Connect

3.

Part of 4-Pair Blue Field

9.

4-Pair Horizontal Cables

4.

From ISDN T-interface Circuit (2-Pair)

10.

Row “A”

5.

To ISDN S/T-interface terminals

11.

Row “B”

6.

2-Pair Cross-Connect

12.

Row “C”

Figure 5-25. Typical Installation of Terminating Resistor Block (110RA1-12)

For point-to-point wiring, the top row connects to the blue station field. The pair connects from the 110RA1-12 to the standard 4-pair circuit. Pair 1 from the 110RA1-12 connects to Pair 1 of the station field, and Pair 2 connects to Pair 3 of the station field.

Two terminal basic multipoint applications are accommodated by connecting row B (output) to the second terminal common to the multipoint circuit.

Page 211
Image 211
Lucent Technologies Release 6 manual T1 R1