DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Add CallVisor ASAI | Page |
Add CallVisor ASAI
Service Interruption
1.Since, if the packet bus is being added, the addition of CallVisor ASAI requires a service interruption, notify the customer in advance as to when the addition will be carried out.
Disable Alarm Origination
1.Enter change system-parameters maintenance and press Enter.
2.Set the Alarm Origination Activated field to n.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets.
3.For some releases of software, disable Cleared Alarm Notification and Restart Notification before submitting the form.
Enter Added Translations
1.On the
2.Also, enable the Packet Bus Activated option on the
3.See DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description, for details on disabling and enabling options on these forms.