DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112 Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-40Emergency Transfer Units and Associated Telephones
5
10. On the trunk identification label at the bottom of the panel, rec ord the trunk
line, extension, and location for each c ircuit.
11. Attac h a label id entifying each voic e terminal desig nated as an
emergency terminal. The labels are provid ed with the unit.
12. Chec k the system for normal operation:
Set the test switch (switch 12) to NORMAL OPERATION.
Ensure the power supp ly is providing -48 VDC at 80 mA maximum.
The power LED should be ON.
Verify there is dial tone on all emergency transfer sets.
If all of the above conditions are not met, replac e the panel.
41 Y-BL TST4 Tip-Emergency Terminal 4
16 BL-Y RST5 Ring -Emergency Terminal 4
42 Y-O TTC5 Tip-PBX Trunk Circuit 5
17 O-Y RTC5 Ring- PBX Trun k Circ uit 5
43 Y-G TTK5 Tip-CO Trunk Circuit 5
18 G-Y RTK5 Ring-CO Trunk Circuit 5
44 Y-BR TLC5 Tip -PBX Li n e Port 5
19 BR-Y RLC5 Ring-PBX Line Port 5
45 Y-S TST5 Tip-Emergency Terminal 5
20 S-Y RST5 Ring-Emergency Terminal 5
46 V-BL COM1 Common 1 Relay Contact
21 BL-V NO1 Normally Open 1 Contact
47 V-O NC2 Normally Closed 2 Contact
22 O-V NC1 Normally Closed 1 Contact
48 V-G COM2 Common 2 Relay Contact
23 G-V NO2 Normally Open 2 Contact
49 V-BR
24 BR-V
50 V-S GRD Ground From PBX
25 S-V -48PX -48V from Alm Panel
Table 5-14. Pin A ssignments for 25-Pair Co nnector Continued
Pin Color Designation Connector/Description
Continued on next page