DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Add | Page |
Add ISDN—BRI
Service Interruption
1.Since, if the packet bus is being added, the addition of
Disable Alarm Origination
1.Enter change system-parameters maintenance and press Enter.
2.Set the Alarm Origination Activated field to n.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets.
3.For some releases of system software, disable Cleared Alarm Notification and Restart Notification before submitting the form.
Save Translations
1.If the system is high or critical reliability, enter status system 1 and press Enter to verify that the system is in the “active/standby” mode.
2.Enter save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card or tape.
3.If the system contains a TN750 Announcement circuit pack, enter display announcements and press Enter.
If administered recorded announcements are listed, enter list configuration
Power Down System
1. If the packet bus is being added, set the main circuit breaker to OFF.