TN1654 DS1 Converter (Release 6r Only)

Page 5-29

E1 Interface Cabling

Figure 5-14 shows typical E1 cabling to the network interface via the coaxial adapter cable. The actual adapter may be different in appearance.

 

 

0027_0 RBP 061896

Figure Notes

 

 

1. 50-Pin Male Connector on Coaxial Adapter Cable

3.

Connect to Quad Cable

2. Coaxial Adapter Cable (With 8 BNC Connectors)

4.

Connect to E1 Network

Figure 5-14. DS1 Converter Connections E1 Only

1.Connect a coaxial adapter cable to the remaining end of the “Y” cable. The opposite end of this cable is wired to a coaxial adapter assembly.

2.Plug a customer-provided quad cable onto the 4 BNC connectors provided on the coaxial adapter.

3.Connect the opposite end of the quad cable to the network interface.