DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

3Install Management Terminal and Activate System

Administer Fiber Links (Release 6r Only)

Page 3-25

10.In the Line Coding: field, enter the line coding information. This information should match the line coding of the facility. For T1, example line coding is b8zs. For E1, example line coding is hdb3.

NOTE:

If this data is not correct, wideband errors (multimedia call handling) may occur.

11.For T1 sites, refer to ‘T1Installations Only’’. For E1 sites, refer to ‘‘E1 Installations Only’.

T1 Installations Only

a. The Framing Mode: field is display only and shows the hardware setting.

b. The DS1CONV-1 Line Compensation: and the DS1CONV-2 Line Compensation: fields are display only and show the hardware setting.

c. In the Facility A Circuit ID: field, enter an optional facility name that is unique to each facility (up to 40 alphanumeric characters). Press Enter.

d. A display similar to the following appears after the fiber link administration is completed:

RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED.

E1 Installations Only

a.Enter y or n in the CRC? field. The “CRC” means Cyclic Redundancy Check. This is an error detection algorithm.

b. The Line Termination: field is display only. A 75 (75 Ohms) or 120 (120 Ohms) typically displays.

c. In the Facility A Circuit ID: field, enter an optional facility name that is unique to each facility (up to 40 alphanumeric characters). Press Enter.

d. A display similar to the following appears after the fiber link administration is completed:

RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED.