DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
TN1654 DS1 Converter (Release 6r Only) | Page |
TN1654 DS1 Converter (Release 6r
Only)
Set Circuit Pack Switches
The configuration switches on the TN1654 must be set before the circuit pack is installed. The TN1654 can be configured for either T1 or E1 operation. All 4 facilities on the circuit pack are configured as a group. It is not possible to have T1 and E1 facilities supported on the same circuit pack at the same time.
E1 facility line termination impedances of 120 Ohms for
Figure 5-11 shows the location of the switches. Table 5-9 shows the switch setting positions and functions.
Table 5-9. TN1654 DS1 Converter Configuration Switches
Switch | Function | Up | Down |
|
|
|
|
|
|
1 | Type of Facility | T1 | E1 |
|
|
|
|
|
|
2 | Span A Line Impedance (E1 Only) | 120 Ohm | 75 Ohm |
|
| Span A Framing (T1 Only) | ESF | D4 |
|
|
|
|
|
|
3 | Span B Line Impedance (E1 Only) | 120 Ohm | 75 Ohm |
|
| Span B Framing (T1 Only) | ESF | D4 |
|
|
|
|
|
|
4 | Span C Line Impedance (E1 Only) | 120 Ohm | 75 Ohm |
|
| Span C Framing (T1 Only) | ESF | D4 |
|
|
|
|
|
|
5 | Span D Line Impedance (E1 Only) | 120 Ohm | 75 Ohm |
|
| Span D Framing (T1 Only) | ESF | D4 |
|
|
|
|
|
|
6 | Force Fiber | Enabled | Disabled |
|
| Scrambling |
|
|
|
|
|
|
|
|
|
|
|
|
|
1.Set the configuration switches on the TN1654 as required per site.
2.Set Switch 6 down (disabled).