DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

3Install Management Terminal and Activate System

Reboot High Reliability System

Page 3-29

Reboot High Reliability System

1.Enter reset system 4.

2.When the login: prompt appears, login as craft.

3.About eight minutes after booting and at the Command: prompt, enter the status spe command.

4.Verify that handshake, shadowing, and refreshed are all shown to be either yes or on.

Enable Duplication and Boot Critical Reliability

System (Release 6r)

1.Enter change system-parameters duplication.

2.Make sure duplication of both SPE and PNC are enabled on the screen that follows the command. Confirm that a y is contained in both fields.

3.Enter save translation.

4.Enter reset system 4 to reboot the system.

5.When login: appears on the screen, login as craft.

6.About eight minutes after booting the system and at the Command: prompt, enter the status spe command.

7.Verify that handshake, shadowing, and refreshed are all shown to be either yes or on.

Administer Attendant Console

1.Enter display system-parameters country-options and press Enter to verify the system’s companding mode for its local stations is set to the desired value (usually, A-Law for Europe and mu-Law for North America and Japan).

2.If necessary, enter Enter to change the these terminals.

change terminal-parameters 603/302B1 and press default system-level parameters and audio levels for

NOTE:

For information about changing the default parameters and audio levels, refer to DEFINITY Application Notes available through the International Technical Assistance Center (ITAC).

3.Administer other forms listed under Attendant Console in DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.