DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
| Page |
When possible, all new and reused wiring installations should use blocks that accept the standard
The ITW Linx Enhanced Protector may be installed in series with existing primary protection. The
The maximum range for
m)when using 24 AWG (#5) (0.26 mm2) wire and 2200 feet (670 m) when using
26 AWG (#4) (0.14 mm2) wire. The range can be extended to 5000 feet (1524 m) using 24 AWG (#5) (0.26 mm2) wire or 4000 feet (1219 m) using 26 AWG (#4) (0.14 mm2) wire with the use of a Data Link Protector (DLP). The DLP is an isolating transformer used to remove phantom power on the system side and
Protector and Data Link Protector Ordering Information
Description | Comcode |
|
|
105581086 | |
|
|
ITW LINX (Gas Tube, Avalanche Suppress) | 406144907 |
|
|
ITW Linx Ground Bar (used with above) | 901007120 |
|
|
ITW Linx Replacement Fuse | 406304816 |
|
|
Data Link Protector (1 circuit) | 103972758 |
|
|
Data Link Protector (8 circuits) | 103972733 |
|
|