DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Off-Premises or Out-of-Building Stations

Page 5-35

When possible, all new and reused wiring installations should use blocks that accept the standard 5-pin plug-in 4C3S-75 protector. However, there are reused wiring installations where this may not be cost effective. For these installations, the ITW Linx protector may be installed. An example of this is where screw-type carbon block protectors (or other non plug-compatible types) are in place and it is too costly to re-terminate the outside plant cable on a 5-pin mounting block for only a few out-of-building terminals.

The ITW Linx Enhanced Protector may be installed in series with existing primary protection. The 4C3S-75 protector cannot be installed in series with other types of primary protection. It must be installed as the only protection on the line entering the building. For the 4C3S-75 protector there are a variety of 25-, 50-, and 100-pair protector panels equipped with 110-type connecting blocks and/or RJ21X connectors. The ITW Linx Enhanced Protector mounts directly on connecting blocks and requires a separate ground bar.

The maximum range for out-of-building digital voice terminals is 3400 feet (1036

m)when using 24 AWG (#5) (0.26 mm2) wire and 2200 feet (670 m) when using

26 AWG (#4) (0.14 mm2) wire. The range can be extended to 5000 feet (1524 m) using 24 AWG (#5) (0.26 mm2) wire or 4000 feet (1219 m) using 26 AWG (#4) (0.14 mm2) wire with the use of a Data Link Protector (DLP). The DLP is an isolating transformer used to remove phantom power on the system side and re-introduce it on the terminal side. When a protector is used, the voice terminal must be locally powered by an external power supply or through the AC power cord provided with some of the 7400-type voice terminals. The protector is installed on the equipment side of the protection in both buildings.

Protector and Data Link Protector Ordering Information

Description

Comcode

 

 

4C3S-75 (Solid State with Heat Coil)

105581086

 

 

ITW LINX (Gas Tube, Avalanche Suppress)

406144907

 

 

ITW Linx Ground Bar (used with above)

901007120

 

 

ITW Linx Replacement Fuse

406304816

 

 

Data Link Protector (1 circuit)

103972758

 

 

Data Link Protector (8 circuits)

103972733

 

 

Page 186