1 Install and Connect Cabinets

 

Connect AC Power and Ground

Page 1-6

 

 

Connect AC Power and Ground

Power Requirements

Table 1-2 shows the power requirements.

Table 1-2. DEFINITY System Power Requirements

Maximum DEFINITY UL Rating Label Power Capacity

Vac In

Iac In

Max W In

BTU/Hr

 

 

 

 

 

 

208

24

3245

11071.26

 

 

 

 

 

 

240

21

3276

11177.71

 

 

 

 

 

 

120

40

3120

10645.44

 

 

 

 

 

 

 

 

 

 

 

J58890CE-1, J58890CE-2, and J58890CH-1

The following procedures apply to the AC-powered PPN and EPN cabinets.

Either of the following power sources can supply 60 Hz power to the AC load in

Release 5 and later systems:

Single-phase, 4-wire, 120/240 VAC supplying 240 VAC. This source has 2 hot wires, 1 ground wire, and 1 neutral wire (J58890CE).

3-phase, 4-wire, 120/208 VAC supplying 208 VAC. This source has 2 hot wires, 1 ground wire, and 1 neutral wire (J58890CE).

Single-phase, 3-wire, 208 or 240 VAC. This source has 2 hot wires and 1 ground wire (J58890CH).

Either of the following power sources can supply 50 Hz power to the AC load in

Release 5 and later systems:

Non-United States 4-wire, Y, 220/380 VAC. This source has 3 hot wires, 1 neutral wire, and 1 ground wire.

Non-United States Delta, 3-wire, 220 or 240 VAC. This source has 3 wires.