DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
4Test the System
LED Indicators | Page | |
|
|
|
Figure Notes |
|
| |
1. | Alarm LED (Red) | 4. | STATUS LEDs |
2. | Test LED (Green) | 5. | SPAN LEDs |
3. | Busy LED (Yellow) |
|
|
Figure 4-2. TN1654 DS1 Converter Circuit Pack LEDs
LEDs on Standby Components
In high and critical reliability systems, duplicated components on standby usually have the yellow LEDs off, with the following exceptions:
■The major, minor and warning alarm LEDs on the SYSAM circuit pack on the standby SPE do not give reliable indications. Note only LEDs on the active SYSAM circuit pack.
■The yellow LED blinks on and off when the standby processor circuit pack is up and standby maintenance is running.
■In high reliability systems with a Center Stage Switch, (duplicated SPE, simplex PNC), the standby Switch Node clock’s yellow LED is off. In critical reliability systems, the standby SNC is located on a separate carrier and normally remains lit.
■Yellow LEDs on power units on standby carriers normally remain lit.