DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
1145B Power Supply | Page |
Install the Expanded Power Distribution Unit
A second power distribution unit can be installed to provide power to additional
!
CAUTION:
Total power cannot exceed 200 Watts. The maximum ISDN terminal mixture is twenty four
The maximum DCP terminal mixture is twenty four
The following items are supplied with each expanded power distribution unit kit:
—One 1146B Power Distribution Unit (comcode 107250995)
—One “T” Cable (comcode 847529872)
—Two
—One
—One Spacer Bracket (comcode 847554441)
Refer to Figure
1. Set the spacer bracket onto the mounting plate and secure with the
x
2.Slide the keyhole slots in the power distribution unit over the shoulder screws.
3.Insert the
4.Set the battery
5.
6.Remove the output power cable between the 1145B and the 1146B units. The cable will not be reused.
7.Connect the P1 connector end of the “T” cable to the bottom power distribution unit. Connect the P2 connector to the top distribution unit. Connect the P3 connector to the 1145B.
8.