Lucent Technologies Release 6 manual Install the Circuit Pack and Cabling E1 Only

Models: Release 6

1 453
Download 453 pages 12.94 Kb
Page 179
Image 179

DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-CarrierCabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

TN1654 DS1 Converter (Release 6r Only)

Page 5-28

1.Connection to the remote-located system is the same as that shown in Figure 5-12 and Figure 5-13.

Table 5-10 shows the “Y” cable lengths and associated comcode numbers.

Table 5-10. “Y” Cable Lengths

Length

Description

Comcode

 

 

 

 

 

 

14

Inches (35.5 cm)

TN1654 to adjacent Expansion Interface

847245750

 

 

 

circuit pack or TN573B Switch Node

 

 

 

 

Interface circuit pack in same carrier

 

 

 

 

 

 

 

70

Inches (177.8 cm)

TN1654 to Expansion Interface circuit

847245768

 

 

 

pack or Switch Node Interface in another

 

 

 

 

carrier

 

 

 

 

 

 

 

14

Inches (35.5 cm)

TN1654 to fiber optic transceiver

847245776

 

 

 

(DC-powered cabinets only). This cable

 

 

 

 

is for intercabinet cabling only.

 

 

 

 

 

 

 

14

Inches (35.5 cm)

TN1654 to adjacent TN570C Expansion

847746641

 

 

 

Interface circuit pack

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

The distinction between facility types is important when using TN1654 circuit packs. The facility used to carry control channel messages between the pair of DS1 converter circuit packs and all packet traffic is known as the primary facility. The facility used to backup and takeover for the primary facility in the event of primary facility failure is known as the secondary facility. The TN1654 allows either facility, A or B, to be a primary channel. The control channel is restricted to only the A or B facilities. This permits full 24-channel access (T1) or 31-channel access (E1) for facilities C and D to support user traffic.

Install the Circuit Pack and Cabling (E1 Only)

The E1 installation is similar to the T1 installation except the H600-348 Quad

Cable and the Channel Service Unit are not used.

NOTE:

The H600-348 Quad Cable can be used on E1, 120 Ohm installations.

1.Install a “Y” cable between the DS1 Converter connector and the Expansion Interface connector. See Figure 5-12. Also refer to Table 5-10 for the “Y” cable lengths and associated comcode numbers.

2.Be sure to label the cables as they are installed.

Page 179
Image 179
Lucent Technologies Release 6 manual Install the Circuit Pack and Cabling E1 Only, Y Cable Lengths Description Comcode