DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112 Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-92Add DS1 Tie and OPS
5
Save Translations
1. If the system is high or c ritical reliability, enter status system 1 and press
Enter to verify that the system is in the “ active/standby” mode.
2. Enter save translation and press Ente r. This instructs the system to take all
translation information in memory and write it to the translation card or
tape.
3. If the PPN contains a TN750 Announcement c irc uit pack, enter list
configuration software-version and press En ter.
If Page 2 of this form shows that recorded announcem ents were saved ,
these announcements can b e restored us ing the restore announcements
command. Enter restore announcements and press Enter .
Enable Customer Options
1. Enter change system-parameters customer-options and p ress Enter.
2. Use these forms to verify the c ustomer options are properly set.
NOTE:
In the Basic Call Setup field, if ISDN-PRI? was set to y be fore the
upgrade, b e sure to set the field back to y.
Resolve Alarms
Examine the alarm log. Resolve any alarms that may exist using

DEFINITY

Enterprise Communications Server Release 6 Maintenance R6vs/si

.
Contact INADS to Enable Customer Options and
Verify Alarm Origination
Be sure the system is part of the existing INADS database by calling the INADS
Database Administrator at the Technical Service Center (TSC). Verify that INADS
can dial into the system and that the system can dial out to INADS.
As part of the system registration process, the INADS Database Administrator
enables Alarm Orig ination and enables c ustomer options.