DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Add DS1 Tie and OPS

Page 5-92

Save Translations

1.If the system is high or critical reliability, enter status system 1 and press Enter to verify that the system is in the “active/standby” mode.

2.Enter save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card or tape.

3.If the PPN contains a TN750 Announcement circuit pack, enter list configuration software-versionand press Enter.

If Page 2 of this form shows that recorded announcements were saved, these announcements can be restored using the restore announcements command. Enter restore announcements and press Enter.

Enable Customer Options

1.Enter change system-parameters customer-options and press Enter.

2.Use these forms to verify the customer options are properly set.

NOTE:

In the Basic Call Setup field, if ISDN-PRI?was set to y before the upgrade, be sure to set the field back to y.

Resolve Alarms

Examine the alarm log. Resolve any alarms that may exist using DEFINITY

Enterprise Communications Server Release 6 Maintenance R6vs/si.

Contact INADS to Enable Customer Options and

Verify Alarm Origination

Be sure the system is part of the existing INADS database by calling the INADS Database Administrator at the Technical Service Center (TSC). Verify that INADS can dial into the system and that the system can dial out to INADS.

As part of the system registration process, the INADS Database Administrator enables Alarm Origination and enables customer options.

Page 243
Image 243
Lucent Technologies Release 6 manual Enable Customer Options, Resolve Alarms