DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Analog Station or 2-Wire Digital Station Example

Page 5-5

Analog Station or 2-Wire Digital

Station Example

This example is typical of the 2-wire digital stations (603E, 84xx, 94xx, 302C), 2-wire analog stations (500, 2500, 71xx), analog CO trunks, DID trunks, and external alarms.

The wiring designations for this example are shown in Figure 5-4.

T

2

28 T.3

R

3

03 R.3

 

 

2500wire RBP 071996

Figure Notes

 

 

1. 2500-Type Analog Station

2. TN2183 Analog Line Circuit Pack

 

 

(Position 1C01)

Figure 5-4. 2500-Type Analog Telephone Wiring

1.Choose a peripheral to connect (such as an analog station or 2-wire digital station).

2.Choose the port circuit pack, its carrier, slot number, and port. For example TN2183 Analog Line, cabinet 1, carrier C, slot 1, port 03.

3.Install cross-connect jumpers to connect the pins from the analog station or 2-wire digital station to the appropriate pins on the port circuit pack. This pinout information is for the TN2183 Analog Line circuit pack.

4.Administer on the management terminal. See DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description, for more details.

Page 156
Image 156
Lucent Technologies Release 6 manual Analog Station or 2-Wire Digital Station Example, Type Analog Telephone Wiring