DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Adjunct Power Connections | Page |
Local and Phantom Power
A console’s maximum distance from the system is limited. See Table
Table 5-4. Attendant Console Cabling Distances
Enhanced Attendant | 24 AWG Wire (0.26 mm2) | 26 AWG Wire (0.14 mm2) | |||
|
|
|
|
| |
Console (302C1) | Feet | Meters | Feet | Meters | |
|
|
|
|
|
|
With Selector Console |
|
|
|
|
|
Phantom powered | 800 | 244 | 500 | 152 |
|
Locally powered | 5000 | 1524 | 3400 | 1037 |
|
|
|
|
|
|
|
Without Selector Console |
|
|
|
|
|
Phantom powered | 1400 | 427 | 900 | 274 |
|
Locally powered | 5000 | 1524 | 3400 | 1037 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Auxiliary Power
!
CAUTION:
Do not use the 329A power unit for the attendant console.
The
![]()
NOTE:
For a console to realize the longest nominal battery holdover, the console’s TN754B or TN413 Digital Line circuit pack should reside in an EPN’s expansion control carrier.
An attendant console can also derive auxiliary power from either:
■Individual 1151A or 1151A2 power supply
■
■
■Bulk power supplies such as the 1145A1
A console’s maximum distance from its auxiliary power source is:
■800 feet (244 m) for a 302A1
■350 feet (107 m) for a 301B1 and 302C1