Lucent Technologies Release 6 manual Test SPE Duplication Memory Shadowing Link

Models: Release 6

1 453
Download 453 pages 12.94 Kb
Page 141
Image 141

DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

4 Test the System

 

Test SPE Duplication Memory Shadowing Link

Page 4-6

 

 

Test SPE Duplication Memory

Shadowing Link

For high and critical reliability systems only.

1.Verify the screen displays: Command:

2.Type test shadow-link and press Enter.

3.Verify the screen displays test results similar to Screen 4-5.

 

 

 

TEST RESULTS

 

 

Port

Maintenance Name

Alt. Name Test No. Result

Error Code

 

SHDW-LNK

 

318

PASS

 

Command successfully

completed

 

 

 

 

 

 

 

 

 

Screen 4-5. Example Test Results for SPE Duplication Memory Shadowing Link

4. If result is FAIL for any test, check the inter-cabinet cables in the PPN.

Page 141
Image 141
Lucent Technologies Release 6 manual Test SPE Duplication Memory Shadowing Link, Type test shadow-link and press Enter