DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

6Test Telephones and Other Equipment

Test Stratum 3 Clock

Page 6-7

Test Stratum 3 Clock

This sections tests the ability of the Stratum 3 clock to correctly provide timing and alarms to the system.

! CAUTION:

The following procedures are destructive to DS1 data and should not be attempted while there are DS1 facilities in active use.

Check for Red LEDs

1.Turn on the Stratum 3 clock and wait 40-50 seconds to allow the system to complete the on-board diagnostics before checking LEDs.

2.If there are any red LEDs, follow the procedures in Table 6-1.

Table 6-1. Stratum 3 Clock LED Indicators

Card

LED Label

Procedure

 

 

 

PAI

REF A

Check that the CI circuit pack on the left is inserted properly.

 

 

Check wiring for DS1 in carrier “A” which connects the system to

 

 

the CSU and the External Synchronization Clock at the MDF

 

 

through a Y-cable assembly. If all else fails to clear the LED then

 

 

replace the circuit pack.

 

 

 

PAI

REF B

Check that the CI circuit pack on the right is inserted properly.

 

 

Check wiring for DS1 in carrier B which connects the system to

 

 

the CSU and the External Synchronization Clock at the MDF

 

 

through a Y-cable assembly. If all else fails to clear the LED then

 

 

replace the circuit pack.

 

 

 

PAI

ST A

Replace the ST3 card

 

 

 

PAI

ST B

Replace the ST3 card

 

 

 

CI

FAIL

Check wiring for its associated DS1 reference and replace the

 

 

circuit pack if necessary

 

 

 

ST3

FAIL

Replace the circuit pack

 

 

 

ST3

LOCK

Ignore this LED

 

 

 

ST3

HOLDOVER

Ignore this LED

 

 

 

ST3

FREE RUN

Ignore this LED

 

 

 

TOCA

FAIL

Replace the circuit pack

 

 

 

TOCA

PORT ALM

Replace the circuit pack if necessary

 

 

 

 

 

 

Page 314
Image 314
Lucent Technologies Release 6 manual Test Stratum 3 Clock, Check for Red LEDs