DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Add DS1 Tie and OPS | Page |
Save Translations
1.If the system is high or critical reliability, enter status system 1 and press Enter to verify that the system is in the “active/standby” mode.
2.Enter save translation. Press Enter. This instructs the system to take all translation information in memory and write it to the translation card or tape.
3.If the system contains a TN750/B Announcement circuit pack, enter display announcements and press Enter. If administered recorded announcements are listed, enter list configuration
Shut Down DEFINITY LAN Gateway System
!
WARNING:
Neglecting to shut down a DEFINITY LAN Gateway assembly before powering down the system cabinet where it resides can damage the LAN Gateway disk.
!
CAUTION:
Save the system parameters if you plan to reuse the current system.
1.Log onto the DEFINITY LAN Gateway.
2.When the main menu appears, select Maintenance.
3.Select Reset System from the Maintenance menu.
4.Select Shutdown from the Reset System menu.
Shut Down DEFINITY AUDIX System
!
WARNING:
Neglecting to shut down an AUDIX assembly before powering down the system cabinet where it resides can damage the AUDIX disk.
1.If a DEFINITY AUDIX resides in the system to be upgraded, shut down the AUDIX assembly and allow the disk to completely spin down.