DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

External Ringing

Page 5-44

External Ringing

Connections for external ringing provided by a device, such as a gong, chime, or bell, are at an information outlet. The system side of the MDF connects to a TN2183 or equivalent analog line circuit pack located in a port carrier. The circuit packs contain 16 ports each.

NOTE:

A maximum of 3 devices can connect to 1 TN2183 circuit pack port.

1.Wire the ringing device to the information outlet as shown in Figure 5-8 and Figure 5-9.

2.Administer per DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.

Queue Warning Indicator

The connections for the queue warning indicator are the same as external ringing. An AC indicator (lamp) such as a 21C49 can be used in a Uniform Call Distribution/Direct Departmental Calling (UCD/DDC) queue.

The lamp connects to an information outlet. The system side of the MDF connects to an analog line circuit pack in a port carrier.

1.Wire the queue warning indicator to the information outlet as shown in Figure 5-8 and Figure 5-9.

2.Administer per DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.

Page 195
Image 195
Lucent Technologies Release 6 manual External Ringing, Queue Warning Indicator