4 Test the System

 

Test Duplicated Switch Processing Element Interchange

Page 4-7

 

 

Test Duplicated Switch Processing

Element Interchange

For high and critical reliability systems only.

1.Verify the screen displays: Command:

2.Type status cabinet < 1-44> and press Enter.

3.Verify the screen displays test results similar to Screen 4-6.

Screen 4-6. Example System Status Report for All Cabinets

4.Note the MODE of SPE 1A and 1B.

5.Type refresh spe and press Enter.

Command successfully completed should be displayed.

6.Type reset system interchange and press Enter. This causes the terminal to log off.

7.Log in as craft again. Remember to use the new password established for craft.

8.Note the MODE for SPE 1A and 1B should have changed from that noted in Step 4.