DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

3Install Management Terminal and Activate System

Administer System Configurations (Release 6r)

Page 3-20

change system-parameters customer-options

Page 1 of 4

OPTIONAL FEATURES

 

G3 Version: V5

Maximum Ports:

14000

Abbreviated Dialing Enhanced List? n

 

CAS Main? y

A/D Grp/Sys List Dialing Start at 01? n

Cvg Of Calls Redirected Off-net? n

Answer Supervision by Call Classifier? n

 

DCS (Basic)? y

ARS? y

DCS Call Coverage? n

ARS/AAR Partitioning? n

Emergency Access to Attendant? y

ASAI Interface? n

Extended Cvg/Fwd Admin? n

ASAI Proprietary Adjuncts Links? n

External Device Alarm Admin? n

ATMS? n

Flexible Billing? n

Audible Message Waiting? n

Forced Entry of Account Codes? n

Authorization Codes? n

Hospitality (Basic)? n

CAS Branch? n

Hopitality (G3V3 Enhancements)? n

 

Hopitality Parameter Reduction? n

(NOTE: You must logoff & login to effect the permission changes.)

Screen 3-6. Typical Customer-Options Form

2.Enable the optional features purchased by the customer (as shown by PEC codes on the Customer Order).

In Release 6 systems, a separate screen offers ASAI capability groups for selection in cases where the ASAI interface has been enabled. Change this screen in the same manner as Page 1 of the customer-options form.

Change and Logoff Critical Reliability System

If a critical reliability system is installed (1 with both processor and PNC

duplicated), follow these steps. Otherwise, proceed to ‘ChangeSite-Data’’ on page 3-21.

NOTE:

Be sure PNC Duplication was set to y in the customer-options form.

1. Log off and log back in as craft.

Page 123
Image 123
Lucent Technologies Release 6 Change and Logoff Critical Reliability System, Screen 3-6. Typical Customer-Options Form