Lucent Technologies Release 6 manual Definity Audix Power Procedures, Power Down the Audix System

Models: Release 6

1 453
Download 453 pages 12.94 Kb
Page 135
Image 135

DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

3Install Management Terminal and Activate System

DEFINITY AUDIX Power Procedures

Page 3-32

DEFINITY AUDIX Power Procedures

Power Down the AUDIX System

A yellow caution sticker on the system’s power unit notifies technicians to shut down the DEFINITY AUDIX System prior to powering down the system.

1.Log into the AUDIX System as craft.

2.Enter the reset system shutdown command. Press Enter once.

NOTE:

Do not press Enter again. This will force the AUDIX to shutdown immediately, dropping all active calls on the AUDIX.

3.The “SHUTDOWN Completed” message appears when the AUDIX is successfully shutdown. This takes about 2 minutes.

4.The AUDIX System can now be removed for service.

Power Up the AUDIX System

If the AUDIX was removed from the cabinet:

1.Re-install the AUDIX and allow it to boot up automatically.

2.Check for AUDIX System errors.

If the AUDIX remained in the cabinet but power was removed from the cabinet:

1.Power up the cabinet. The AUDIX reboots automatically.

2.Check for AUDIX System errors.

If the AUDIX remained in the cabinet and the cabinet was not powered down:

1.At the AUDIX console, hold the crtl key and enter cc.

2.Enter 5 at the prompt. In about 2 minutes, the AUDIX boots up.

3.When the system initialization is complete, log in as craft.

4.Check for AUDIX System errors.

Page 135
Image 135
Lucent Technologies Release 6 Definity Audix Power Procedures, Power Down the Audix System, Power Up the Audix System