DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
3Install Management Terminal and Activate System
DEFINITY AUDIX Power Procedures | Page |
DEFINITY AUDIX Power Procedures
Power Down the AUDIX System
A yellow caution sticker on the system’s power unit notifies technicians to shut down the DEFINITY AUDIX System prior to powering down the system.
1.Log into the AUDIX System as craft.
2.Enter the reset system shutdown command. Press Enter once.
![]()
NOTE:
Do not press Enter again. This will force the AUDIX to shutdown immediately, dropping all active calls on the AUDIX.
3.The “SHUTDOWN Completed” message appears when the AUDIX is successfully shutdown. This takes about 2 minutes.
4.The AUDIX System can now be removed for service.
Power Up the AUDIX System
■If the AUDIX was removed from the cabinet:
1.
2.Check for AUDIX System errors.
■If the AUDIX remained in the cabinet but power was removed from the cabinet:
1.Power up the cabinet. The AUDIX reboots automatically.
2.Check for AUDIX System errors.
■If the AUDIX remained in the cabinet and the cabinet was not powered down:
1.At the AUDIX console, hold the crtl key and enter cc.
2.Enter 5 at the prompt. In about 2 minutes, the AUDIX boots up.
3.When the system initialization is complete, log in as craft.
4.Check for AUDIX System errors.