DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

CAMA/E911 Installation

Page 5-135

 

 

 

 

 

Page 1 of 11

 

TRUNK GROUP

 

 

 

 

 

Group Number: 1

Group Type: cama

 

CDR Reports: y

Group Name: cama Trunk Group - E911 COR:

1

TN:

1

TAC:

701

Direction: outgoing

Outgoing Display?

y CESID I

Digits Sent:

0

 

Busy Threshold:

99

 

 

 

 

TRUNK PARAMETERS

Trunk Type: wink-start

Outgoing Dial Type: r1mf

Trunk Termination: rc

Screen 5-1. CAMA Trunk Group form (page 1)

2.On Trunk Group screen (page 1), in the Group Type: field, enter cama.

3.In the Group Name: field, enter the desired name.

4.In the TAC: field, enter the desired trunk access code.

5.In the Outgoing Display: field, enter y.

6.In the CESID I Digits Sent: field, enter the number directed by the Central Office (CO) or the Public Safety Answering Point (PSAP).

7.Scroll to page 3 of the form.

Page 3 of 11

TRUNK GROUP

ADMINISTRABLE TIMERS

Outgoing Disconnect (msec): 400

Cama Outgoing Dial Guard (msec): 75

Outgoing Glare Guard (msec): 1000

Cama Wink Start Time (msec): 5000

Outgoing End of Dial (sec): 1 Outgoing Seizure Response (sec): 4

Disconnect Signal Error (sec): 30

Screen 5-2. Administrable Timers form (page 3)

Page 286
Image 286
Lucent Technologies Release 6 manual Screen 5-1. Cama Trunk Group form, Screen 5-2. Administrable Timers form