2Install Telecommunications Cabling

Cable Installation

Page 2-23

Connect Trunk Pairs to Cabinet Using Jumper

Wires To Establish 3-Pair Modularity

Figure 2-13 on page 2-23 and Figure 2-14 on page 2-24 show trunk pairs connected to the cabinet with jumper wires to establish 3-pair modularity.

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16

17 18 19 20 21 22 23 24

1 4 7 10 13 16 19 22

1

4

7

10 13 16 19 22

1

4

7

10 13 16 19 22

r758425b MMR 031496

Figure Notes:

 

 

1.

Green Field

3.

Pairs

2.

1-Pair Jumpers

4.

Purple Field

Figure 2-13. 3-Pair Modularity for Trunk Pairs for 1-Pair Trunks

To connect the trunk pairs to the purple field:

1.Connect B25A cables between the network interface and the sneak fuse panels. See Figure 2-13.

2.Connect A25D/B25A cables from the sneak fuse panels to the 110-type terminal block-type connecting block connectors in the green field.

3.Connect 1-pair patch cords/jumper wires from each 110-type terminal block row in the green field to the 110-type terminal block rows in the purple field for 1-pair Central Office (CO) trunks or in Figure 2-14 on page 2-24 for 3-pair tie trunks.