DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
DS1 Tie Trunk Example | Page |
DS1 Tie Trunk Example
DS1 tie trunks provide a 1.544 Mbps digital data service between 2 collocated systems or between the system and a data network using T1 carrier facilities. DS1 tie trunk circuit packs provide connection capability to the DS1 facility.
The following cables can be used to connect DS1 tie trunk circuit packs to DS1 digital facilities:
■C6C connector cable (comcode 104307327) —
■C6D connector cable (comcode 104307376) —
■C6E connector cable (comcode 104307434) —
■C6F connector cable (comcode 104307475) —
Table 5-1. Pinout of C6F Cable
Wire Color | Lead Designation | Pin Number | |
White/Green | LI (High Side) | 47 |
|
Green | LI | 22 |
|
White/Brown | LO | 48 |
|
Brown | LO (High Side) | 23 |
|
White/Slate | LBACK2 | 49 |
|
Slate | LBACK1 | 24 |
|
|
|
|
|
Collocated DS1 Tie Trunks
Connection to 2 TN722B DS1 Tie Trunk circuit packs in collocated systems can include a C6D cable for distances up to 50 feet (15.24 m). For distances over 50 feet (15.24 m) and up to 1310 Feet (399.3 m) maximum, use C6E cables.