Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

2 Install Telecommunications Cabling

 

Station Circuit Distribution from Equipment Room

Page 2-33

 

 

Satellite Locations

Satellite locations are closets that provide an administration point (using cross-connect equipment) for station cables and where adjunct power may be applied. The station cable circuits from the equipment room MDF are 3-pair. At the satellite location, 4-pair circuits run to the information outlets. The hardware used is 110-type terminal blocks.

Satellite Locations Using 110-Type Hardware

Each terminal block has a 3-pair (white field) and a 4-pair (blue field) located on the same terminal block.

The 110A-type terminal block that can be used is the 110AE1-75FT. It must be field-terminated to both the white and blue fields.

The 300-pair 110P-type terminal blocks that can be used are:

110PE1-300CT/FT 25-pair connector on the white field and field-terminated on the blue field

110PE1-300FT Field-terminated on both the white and blue fields

The 900-pair 110P-type terminal blocks that can be used are:

110PE1-900CT/FT 25-pair connector on the white field and field-terminated on the blue field

110PE1-900FT Field-terminated on both the white and blue fields

Station Circuit Distribution from

Equipment Room

This section explains the station circuit distribution from the equipment room to the information outlets for new wiring installations. Example connection diagrams are provided to show the options for running and connecting the station cables.

If most of the telephones/voice terminals that require remote powering are within 250 feet (76.2 m) of the equipment room, 4-pair station circuits are run from the equipment room to the information outlets. If this is not the case, or if the customer requires 2-pointadministration, 3-pair station circuits are run from the equipment room to satellite locations. Then, the 4-pair station circuits are run from the satellite locations to the information outlets.

A list of voice and data terminals that can be connected to the system is provided in Table 2-4 on page 2-40. A list of administration terminals that can be connected to the system is provided in Table 2-5 on page 2-44.