DEFINITY Enterprise Communications Server Release 6

Issue 5

Installation and Test for Multi-Carrier Cabinets 555-230-112

May 1998

 

 

5Install and Wire Telephones and Other Equipment

Add Packet Bus to R6si

Page 5-113

Add Packet Bus to R6si

Standard Reliability R6si System

Disable Alarm Origination

1.Enter change system-parameters maintenance and press Enter.

2.Set the Alarm Origination Activated field to n.

! CAUTION:

If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets.

3.For some releases of software, disable Cleared Alarm Notification and Restart Notification before submitting the form.

Save Translations

1.If the system is high or critical reliability, enter status system 1 and press Enter to verify that the system is in the “active/standby” mode.

2.Enter save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card or tape.

Install Circuit Packs

1.Power down the PPN, then EPN1, and then EPN2 as required.

2.At the PPN, install the appropriate circuit packs. See Table 5-20.

Table 5-20. Circuit Pack Locations for Packet Bus in R5si+m PPN

Circuit Pack

Carrier

Quantity

Slot

 

 

 

 

TN778

Control Carrier A

1

PACKET CONT

 

 

 

 

TN570

Control Carrier A

1 or 21

EXPN INTFC/1 and /2

TN771C

Control Carrier A

12

Any Available Port Slot

1.Quantity of this pack should equal the number of EPNs.

2.Optional for digital trunk testing.

Page 264
Image 264
Lucent Technologies Release 6 manual Add Packet Bus to R6si, Standard Reliability R6si System Disable Alarm Origination