DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
555-230-112 Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-113Add Packet Bus to R6si
5
Add Packet Bus to R6si

Standard Reliability R6si System

Disable Alarm Origination
1. Enter change system-parameters maintenance and press En ter.
2. Set the Alarm Origination Activated field to n.
!CAUTION:
If you do not disable Alarm Orig ination, the system may generate
alarms, resulting in unnec essary trouble ticke ts.
3. For some releases of software, disable Cleared Alarm
Notification and Restart Notification before submitting the
form.
Save Translations
1. If the system is high or c ritical reliability, enter status system 1 and press
Enter to verify that the system is in the “ active/standby” mode.
2. Enter save translation and press Ente r. This instructs the system to take all
translation information in memory and write it to the translation card or
tape.

Install Circuit Packs

1. Power d own the PPN, then EPN1, and then EPN2 as required.
2. At the PPN, install the appropriate c ircuit packs. See Table 5-20.
1. Quantity of this pack should equal the number of EPNs.
2. Optional for digital trunk testing.
Table 5-20. Circuit Pack Loca t ions for Packet Bus in R5si+m PPN
Circuit Pack Carrier Quantity Slot
TN778 Control Carrier A 1 PACKET CONT
TN570 Control Carrier A 1 or 21EXPN INTFC/1 and /2
TN771C Control Carrie r A 12Any Available Port Slot