DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Add Packet Bus to R6si | Page |
Add Packet Bus to R6si
Standard Reliability R6si System
Disable Alarm Origination
1.Enter change system-parameters maintenance and press Enter.
2.Set the Alarm Origination Activated field to n.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, resulting in unnecessary trouble tickets.
3.For some releases of software, disable Cleared Alarm Notification and Restart Notification before submitting the form.
Save Translations
1.If the system is high or critical reliability, enter status system 1 and press Enter to verify that the system is in the “active/standby” mode.
2.Enter save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card or tape.
Install Circuit Packs
1.Power down the PPN, then EPN1, and then EPN2 as required.
2.At the PPN, install the appropriate circuit packs. See Table
Table
Circuit Pack | Carrier | Quantity | Slot |
|
|
|
|
TN778 | Control Carrier A | 1 | PACKET CONT |
|
|
|
|
TN570 | Control Carrier A | 1 or 21 | EXPN INTFC/1 and /2 |
TN771C | Control Carrier A | 12 | Any Available Port Slot |
1.Quantity of this pack should equal the number of EPNs.
2.Optional for digital trunk testing.