DEFINITY Enterprise Communications Server Release 6 | Issue 5 |
Installation and Test for | May 1998 |
|
|
5Install and Wire Telephones and Other Equipment
Add Code Calling Access | Page |
Add Code Calling Access
The tones for the Code Calling feature are generated by the TN756, TN768,
TN780, TN2182, or TN419B
Install a TN763 (or a
Administer the form listed under “Code Calling Access” in DEFINITY Enterprise
Communications Server Release 6 Administration and Feature Description.
Add Speech Synthesis
The TN725B Speech Synthesizer circuit pack is required when the Voice Message Retrieval, Automatic Wakeup, or Do Not Disturb features are activated. The TN725B circuit pack does not require administration.
1.Determine the port assignment of the Speech Synthesizer circuit pack to be added.
2.Install the TN725B Speech Synthesizer circuit pack in the designated carrier slot.
Add Pooled Modem
Modem Pooling supports 2 kinds of conversion resources: “integrated” and “combined.” The integrated type requires a TN758 Pooled Modem circuit pack for each 2 conversion resources provided.
The combined type requires a port of a TN754, TN413, or TN2136 Digital Line circuit pack and a port of either an
1.Determine the port assignment of the circuit pack to be added (if required).
2.Install the appropriate circuit pack in assigned carrier slot (if required).
3.Administer the forms listed under “Modem Pooling” in DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.