Moxa Technologies C168HS RS-422 Cable Wiring for Opt8J/F/Z, Opt8D DTE Device DB9 Male DB25 Male

Page 83

Connection Option (Opt8x) and Cable Wiring

Opt8D

PC COM2 port, Serial Printer, Terminal, or any DTE Device

Opt8D

 

 

 

DTE Device

DB9 Male

 

 

 

DB25 Male

RxD

2

 

2

TxD

 

TxD

3

3

RxD

GND

5

 

7

GND

 

RTS

7

4

RTS

CTS

8

5

CTS

DTR

4

6

DTR

DSR

6

20

DSR

DCD

1

8

DCD

RS-422 Cable Wiring for Opt8J/F/Z

RS-422 connection boxes designed for Smartio C168 Series are:

Opt8J: Connection box with 8 female RS-422/485 DB25 ports. Set the port switch to OFF position (RS-422) for the desired port(s).

Opt8F: Connection box with 8 female RS-422 DB25 ports and Max. 500V DC isolation protection which prevents damage caused by high potential voltage.

Opt8Z: Connection box with 8 female RS-422 DB25 ports but without isolation protection.

Smartio C168H/HS User’s Manual 5-7

Image 83
Contents May 1999 6th Edition Smartio C168H/HS User’s ManualDisclaimer Copyright NoticeTrademarks Moxa Internet Services Troubleshooting Hardware InstallationSoftware Installation Connection Option Opt8x and Cable WiringTable of Contents Technical Reference Connection Option Opt8x and Cable WiringTroubleshooting Serial Programming ToolsOverview Smartio The Smart Multiport Async SolutionsJP1 Quick InstallationWide Applications Introduction Surge ProtectionOperating System Support Moxa Serial Comm ToolsUart FeaturesOpt8A/Opt8B/Opt8S Check ListIntroduction Opt8F/Opt8Z Opt8C/Opt8DIntroduction Opt8J RS-422 ModeRS-485 Mode Installation GuideINT Vector 0x1C0 Default SettingsSmartio C168 Series AddressHow to Do Quick Hardware Installation Quick Hardware InstallationConfiguration changed Hardware Installation with IO-IRQ UtilityIO-IRQ Utility and Hardware Configuration Hardware Installation Speed IRQHardware Installation Normal Speed Spectrum High Speed Spectrum Windows NT Software InstallationInstalling Driver Software Installation 4Smartio C168H/HS User’s Manual Tx Fifo Size Port NumberRx Fifo Trigger 6Smartio C168H/HS User’s Manual Configuring Board and Port 8Smartio C168H/HS User’s Manual Driver Windows 95/98Updating Driver Removing Driver10Smartio C168H/HS User’s Manual Software Installation 12Smartio C168H/HS User’s Manual Software Installation 14Smartio C168H/HS User’s Manual Updating Driver 16Smartio C168H/HS User’s Manual DOS Driver Setup Software Installation 20Smartio C168H/HS User’s Manual Software Installation Loading Driver Unloading Driver Unix# cd # /tmp/moxa/mxinstall# moxaadm SCO UnixFor SCO UNIX/OpenServer For Unix SVR4.2 For SCO UNIX/OpenServerFor Unix SVR4.2 Moxa TTY Device Naming Convention Administration Utility moxaadm Baud Rate SettingsNon-Modem and Modem Baud Rate Software Installation Basic ConfigurationBaud Rate Mapping Advanced ConfigurationLabel High/Normal Speed High Speed Low Band High Band RTS/CTS Hardware Flow Control Port MonitoringTx Fifo Trigger Software Installation Terminal Emulation Driver Removal SCO UNIX/OpenServer Setting Moxa Ports to Terminal36Smartio C168H/HS User’s Manual Windows NT and Windows 95/98 InstallationUtilities PComm Programming LibrarySerial Programming Tools Diagnostic for Moxa boards only Monitor for Moxa boards under Windows NT Only Serial Programming Tools Terminal Emulator Programming the Moxa Ports Extended Unix Ioctl CommandsSyntax for Unix SVR4.2 Syntax for SCO UNIX/OpenServerMtcrts Mtcdtr Mstatus Mhwflow 12Smartio C168H/HS User’s Manual Utilities Terminal Emulator DOS API-232 Library Data Scope Diagnose RS-485 Programming for Opt8JThere is a dedicated RS-485 SolutionFunction in PComm or API-232 library. It RS-232 Cable Wiring for Opt8A/B/C/D/S Connection Option Opt8x and Cable WiringOpt8D DTE, DB9 Male Opt8A/S DCE, DB25 FemaleOpt8B/C DTE, DB25 Male RTS CTS DSR DTR GND DCD Type 1 To connect Smartio C168 Series to a DTE deviceType 2 To connect Smartio C168 Series to a DCE device Opt8B/C Opt8B/C DTE Device DB25 Male Opt8D DTE Device DB9 Male DB25 Male RS-422 Cable Wiring for Opt8J/F/ZOpt8J/F/Z Followings are operation modes for RS-422 Opt8J RS-485 Cable Wiring for Opt8JRS-422/485 Impedance Matching 12Smartio C168H/HS User’s Manual Hardware causes and solutions General TroubleshootingSoftware Causes and Solutions Io-irq StepRemove the jumper on position JP1 Windows NT system panic blue screen COM number of the Smartio C168 Series conflicts with othersSoftware Cause and Solution Under UNIXs, the newly rebuilt kernel could not boot 8Smartio C168H/HS User’s Manual Appendix SpecificationsSCO Xenix QNX Uart 16C550CIO/ Address Device PC I/O Port Address MapPin no Signal DB62 Connector PinoutsPC Host Moxa Driver Version Moxa hardware settingsOperating System o Return Procedure