Pelco VMX300-E installation manual External Devices, Direct Serial Connection

Page 31

EXTERNAL DEVICES

External devices can be connected either with a direct serial connection or with an Internet Protocol connection. An overview of each type of connection is provided below; refer to the specific instructions provided for each type of external device in the following pages.

Direct Serial Connection

A direct serial connection means connecting the device to one of the COM ports on the VMX300(-E) rear panel. If your system contains more than one VMX300(-E) workstation, be sure to connect the device to the workstation that the device driver runs on.

VMX300(-E)

EXTERNAL DEVICE

SERIAL DATA

Figure 24. Sample of a Direct Serial Connection for an External Device

The VMX300(-E) provides the following types of COM ports:

RS-232:COM 1, COM 2

RS-422:COM 3, COM 4

After installing system hardware, ensure that the device’s internal settings match the VMX300(-E) COM port serial communication settings. If they do not match, you must either

configure the internal settings to match the VMX300(-E) COM port default settings, as identified in Table F, or

change the VMX300(-E) COM port settings to match the device; instructions are provided in the Appendix on page 42.

Table F. Default Settings for VMX300(-E) COM Ports

VMX300(-E) COM Port

Default Settings

 

 

COM 1, COM 2

RS-232, 9600 baud, no parity, 8 data bits, 1 stop bit

 

 

COM 3, COM 4

RS-422, 2400 baud, no parity, 8 data bits, 1 stop bit

 

 

Table G provides the pin assignments for the VMX300(-E) COM ports and Figure 25 on page 28 illustrates the RS-422 wall block connections.

Table G. VMX300(-E) COM Port Pin Assignments

RS-232 Pin Assignments (COM 1, COM 2)

PIN 2

RX

 

 

PIN 3

TX

 

 

PIN 5

Ground

 

 

RS-422 Pin Assignments (COM 3, COM 4)

PIN 2

Rx+

 

 

PIN 3

Tx-

 

 

PIN 5

Ground

 

 

PIN 7

Tx+

 

 

PIN 8

Rx-

 

 

C1552M-C (7/07)

27

Image 31 Contents
Rear View AddendumVMX300-E Monitor Outputs How to Connect a Single Monitor to a VMX300-E WorkstationModel Workstations VMX300-E Analog Video InputsISO9001 Installation Manual Page Contents List of Tables List of IllustrationsImportant Safety Instructions Video Quality Caution Regulatory NoticesDescription VMX300 Models ModelsVMX300-E-CL-0 Client VMX300-E ModelsCompatible Products VMX300E-B Backup ServerDocumentation Resources Typical Applications Matrix SwitchersPelco Ascii Switchers Coaxitron and Fixed Camera Transmission Looping Camera Outputs DX8000 and DX9000 Series DvrsConnecting a DVR Method Network Pelconet Transmission SystemsNetworkip Example 3 of a PelcoNet Configuration Sample VMX300-E System with the NVR300 NVR300 Network Video RecorderParts List InstallationUSER-SUPPLIED Parts Mounting Rack Mount InstallationFront View Rear View VMX300-E Connections to the Network VMX300-E ConnectionsVMX300-E Keyboard and Mouse Right VGA Monitor Video Input Direct Serial Connection External DevicesInternet Protocol KBD300A Direct Serial Connection KBD300A KeyboardNetwork Keyboard Communications tab, Connection Type Select Direct Serial SPECTRA/ESPRIT Control ConnectionsConnect Ground on ONE END only CM6700 SwitcherCM6800 Port Programming CM6800 SwitcherAlternate CM6800 Connection CM9700 Matrix Switching Systems Alternate CM9700 Connection CM9760-ALM Alarm Interface Unit RDA RDB RS-422 Reversed Cable CM9760-REL Relay Interface UnitIP-BASED Devices Serial Output DevicePower Cables Appendix Changing the Port Settings of a VMX300-E COM PortELECTRICAL/ Video SpecificationsPage Product Warranty and Return Information ISO9001