Page 22

2. Basic Configuration

Table 2-1. Easy Install Configuration Options (3 of 7)

TS Access

Possible Settings: None, DLCI, VPI,VCI, DLCI_on_VPI,VCI

Default Setting: [Depends on model]

Specifies the type of Virtual Circuit (VC) by which special troubleshooting (TS) access is provided to service providers.

Display Conditions – This setting does not appear if Service Type is PPP.

None – No special troubleshooting link is defined.

DLCI – (Models whose network interface does not support ATM.) Allows the user to select a frame relay DLCI to be designated for special troubleshooting access.

VPI,VCI – (Models whose network interface supports ATM.) Specifies an ATM VC on a specific ATM VPI,VCI for TS access. It specifies the VPI and VCI on the network interface for service provider troubleshooting. ATM data is presumed to be encapsulated according to RFC 1483. VPI 0,VCI 35 is the default management path between the FrameSaver device and the DSLAM. The VPI and VCI are entered separately.

VPI range is 0–15.

VCI range is 32–255.

DLCI_on_VPI,VCI – (Models whose network interface supports ATM.) Specifies a frame relay DLCI VC on a specific ATM VPI,VCI for TS access. DLCI range is 16–1007. ATM data is presumed to be encapsulated according to RFC 1490.

Create a Dedicated Network Management Link

Possible Settings: 16 – 1007

Default Setting: Initially blank

Enter a DLCI number and (for units that support ATM) VPI,VCI for a dedicated network management PVC.

NOTE: With the cursor on the Create a Dedicated Network Management Link field, press Enter. The Which DLCI would you like to Create a Dedicated Frame Relay Management PVC on? prompt appears. If the DLCI entered is over an ATM link, prompts for VPI and VCI also appear.

Display Conditions – This setting does not appear if Service Type is PPP.

16 – 1007 – Specifies the DLCI number be used.

Ethernet Management Options Screen

For units with an Ethernet port, provides a link to the Ethernet Management Options Screen. Press Enter and the screen appears. After configuring Ethernet options, press the Esc key to return to the Easy Install screen.

Time Slot Assignment Screen (9123, 9126, 9128)

For units with a T1 network interface, provides a link to the timeslot assignment screen appropriate to the Service Type. Press Enter and:

If Service Type is Frame Relay, the Network 1 Frame Relay Assignments screen

￿appears.

If Service type is Leased Line, the Sync Data Port Assignments screen appears.

After configuring timeslots, press the Esc key to return to the Easy Install screen.

2-6

December 2002

9000-A2-GB31-00

Image 22
Contents FrameSaver SLV Copyright 2002 Paradyne Corporation All rights reserved Contents Contents Feature-Specific Configuration IndexContents December Document Organization Purpose and Intended AudienceSection Description FrameSaver SLV reference library contains Product-Related DocumentsDocument Number Document Title Other FrameSaver model-specific documentation includesVii Convention Used When Used Conventions UsedConfiguration Procedures Configuration Menu Configuration Menu ExampleConfiguration Option Areas Configuration Option Area DescriptionAccessing and Displaying Configuration Options Main Menu→ ConfigurationChanging Configuration Options Configuration→PVC ConnectionsSaving Configuration Options Basic Configuration Using the Easy Install Feature Main Menu→ Easy InstallEasy Install Screen Example DDS Interface Easy Install Configuration Options 1 Service Type Possible Settings Frame Relay, Leased Line, PPPEasy Install Configuration Options 2 DslamEthernet Management Options Screen Easy Install Configuration Options 3Create a Dedicated Network Management Link Time Slot Assignment Screen 9123, 9126Network 1 Line Coding Format 9123, 9126 Easy Install Configuration Options 4Network 1 Line Framing Format 9123, 9126 Network 1 Line Build Out 9520, 9520-ILMDS0 Base Rate 9123, 9126 Easy Install Configuration Options 5Network 1 DSL Line Rate Mode 9720, 9783 Network 1 Port Type 9820-2M, 9820-8M384 Easy Install Configuration Options 6Network 1 DSL Line Rate 784Easy Install Configuration Options 7 Network 1 ChannelUsing RIP with FrameSaver SLV CSU/DSUs Configuration→Data Ports→DLCI RecordsMain Menu→ Control→System Information Entering System Information and Setting the System ClockIf the selection is Enter Setting Up Auto-Configuration Main Menu→ Auto-ConfigurationMain Menu→ Auto-Configuration→Frame Relay Discovery Mode Selecting a Frame Relay Discovery ModeDiscovery Mode Configuration Description Takes place Automatically Removing a Circuit Configuration Options Configuration Option TablesConfiguration Options Main Menu→ Configuration→System →Frame Relay and LMI Configuring the Overall SystemConfiguring Frame Relay and LMI for the System CSU/DSUs System Frame Relay and LMI Options 1System Frame Relay and LMI Options 2 System Frame Relay and LMI Options 3 LMI Heartbeat T1 Possible Settings 5, 10, 15, 20, 25 LMI Status Enquiry N1 Possible Settings 1, 2, 3, 4System Frame Relay and LMI Options 4 Possible Settings Independent, Port-1FollowsNet Configuring PPP OptionsMain Menu→ Configuration→System→PPP PPP OptionsConfiguring Class of Service Definitions Field Setting After RfcCodePoints SelectedMeasure Latency & Availability Class of Service DefinitionsClass of Svc Name Code Points AssignedCode Pnt Code Point DefinitionsCode Point Definitions NameService Level Verification Options 1 Configuring Service Level Verification OptionsMain Menu→ Configuration→System→Service Level Verification SLV Type Available Settings Standard, COS 1-COSSLV Timeout Error Event Threshold Service Level Verification Options 2Dlci Down on SLV Timeout SLV Timeout Clearing Event ThresholdSLV Latency Clearing Event Threshold Service Level Verification Options 3SLV Packet Size bytes Test Timeout Configuring General System OptionsMain Menu→ Configuration→System→General General System Options 1General System Options 2 System Alarm Relay General System Options 3Configuring the Network Interface Configuring Physical InterfacesMain Menu→ Configuration→Network→Physical T1 Network Interface T1 Network Physical Interface Options 1Network Initiated LLB T1 Network Physical Interface Options 2Transmit Timing Network Initiated PLBAnsi Performance Report Messages Network Initiated Dclb Possible Settings Disable, V.54&ANSIT1 Network Physical Interface Options 3 ESFT1 Network Physical Interface Options 4 Circuit IdentifierT3 Network Physical Interface Options T3 Network InterfaceLine Build Out DDS Network Interface DDS Network Physical Interface Options 1DSU Latching Loopback DDS Network Physical Interface Options 2Require DSU Latching Loopback Preamble 10. Idsl Network Physical Interface Options Operating Rate Possible Settings AutoRate, 64, 128Idsl Network Interface Channel11. Sdsl Network Physical Interface Options Line Rate Mode Possible Settings Hunt, AutoRate, FixedSdsl Network Interface DSL Line Rate KbpsShdsl Network Interface 12. Shdsl Network Physical Interface Options 1PSD Mask Synchronous Network Interface12. Shdsl Network Physical Interface Options 2 Port TypeMonitor CTS Monitor DSRMonitor Rlsd Hssi Network Interface 14. Hssi Network Data Port Physical Interface OptionsData Port Physical Interface Configuring a User Data Port CSU/DSUsMain Menu→ Configuration→Data Ports→Physical 15. V.35 Data Port Physical Interface Options 1Max Port Rate Port Use Possible Settings Frame Relay, Synchronous Data15. V.35 Data Port Physical Interface Options 2 Port Base RateTransmit Clock Source 15. V.35 Data Port Physical Interface Options 3Monitor RTS Monitor DTR 15. V.35 Data Port Physical Interface Options 4Port DTE Initiated Loopbacks 15. V.35 Data Port Physical Interface Options 5 Action on Network Yellow AlarmInvert Transmit and Receive Data EIA-530-A/X.21/V.35 Data Port Physical Interface 15. V.35 Data Port Physical Interface Options 6Transmit Clock Source Hssi Data Port Physical Interface 17. Hssi Data Port Physical Interface Options 117. Hssi Data Port Physical Interface Options 2 17. Hssi Data Port Physical Interface Options 3 Main Menu→ Configuration→T3 User Ports→ Physical Configuring the T3 User Port 9520-ILM18. T3 User Port Physical Interface Options 19. DSX-1 Physical Interface Options 1 Configuring the DSX-1 Interface 9126Main Menu→ Configuration→DSX-1 Interface Status19. DSX-1 Physical Interface Options 2 Send All Ones on DSX-1 FailureService Profile ID Spid 1 or Configuring the Isdn DBM Interface 9126, 9128Main Menu→ Configuration→ISDN→Physical 20. Isdn BRI DBM Physical Interface Options 912621. Isdn PRI DBM Physical Interface Options 9128 1 Switch Type Possible Settings NI-2, ATT4ESS, ATT5ESSLocal Phone Number Line Build Out LBO Possible Settings 0.0, -7.5, -15 21. Isdn PRI DBM Physical Interface Options 9128 221. Isdn PRI DBM Physical Interface Options 9128 3 22. Isdn Link Profile Options 1 Setting Up Isdn Link Profiles 9126, 9128Main Menu→ Configuration→ISDN→ISDN Link Profiles Link NameInbound Calling ID 1 or 22. Isdn Link Profile Options 2Outbound Phone Number Maximum Link Rate KbpsCaller Identification Method Assigning Time Slots/Cross Connections22. Isdn Link Profile Options 3 Alternate Outbound Phone NumberValue Meaning Assigning Time Slots to the Network InterfacePPP Assigning DSX-1 Time Slots to the Network Interface DSX-1 to Network Time Slot Assignment Screen Example DSX-1 Signaling Assignments and Trunk Conditioning RBS Idle PLAR3idle Synchronous Data Port Assignment Screen Example Clearing Assignments 24. Interface Frame Relay Options 1 Configuring Frame Relay for an InterfaceLMI LMI Parameters 24. Interface Frame Relay Options 2Traffic Policing Frame Relay DS0s Base Rate24. Interface Frame Relay Options 3 Main Menu→ Configuration→Network/Data Ports → PPP Configuring PPP for an Interface25. Interface PPP Options 26. Dlci Record Options 1 Manually Configuring Dlci RecordsDlci Number 26. Dlci Record Options 2 CIR bpsCommitted Burst Size Bc Bits 26. Dlci Record Options 3Excess Burst Size Bits Dlci Priority Backup Group Possible Settings A, B, C, . . . Z, None26. Dlci Record Options 4 Outbound Management Priority27. Circuit Records Options 1 Configuring Circuit Records for the Network InterfaceMain Menu →Configuration →Network →Circuit Records VPI,VCI Number27. Circuit Records Options 2 9783 0 9788 0Excess Burst Size Be Bits 27. Circuit Records Options 39783 9788 Cell Delineation Error Event Threshold Configuring ATM for the Network InterfaceMain Menu→ Configuration→Network →ATM 28. Network ATM Options29. PVC Connection Options 1 Configuring PVC ConnectionsMain Menu→ Configuration→PVC Connections Source DlciPrimary Destination Link 29. PVC Connection Options 2Source Edlci Primary Destination DlciAlternate Destination Link 29. PVC Connection Options 3Primary Destination Edlci Alternate Destination Dlci29. PVC Connection Options 4 Alternate Destination EdlciMain Menu→ Configuration→IP Path List Static Configuring the IP Path List30. IP Path List Setting Up Management and Communication Options Configuring Node IP Information 31. Node IP Options 131. Node IP Options 2 31. Node IP Options 3 TS Access Management LinkManagement MTU Size 31. Node IP Options 4 TS Management Snmp ValidationConfiguring Management PVCs 32. Management PVC Options 1Payload Managed 32. Management PVC Options 2Set DE 32. Management PVC Options 3 Primary Dlci32. Management PVC Options 4 Primary EdlciAlternate Dlci 32. Management PVC Options 5Alternate Edlci 32. Management PVC Options 6 Encapsulation33. General Snmp Management Options 1 Configuring General Snmp ManagementName 1 Access Snmp ManagementName 2 Access Configuring Telnet and/or FTP Session Support33. General Snmp Management Options 2 34. Telnet and FTP Session Options 1 Telnet Login RequiredTelnet Session 34. Telnet and FTP Session Options 2 NMS IP Validation Configuring Snmp NMS Security35. Snmp NMS Security Options 1 Number of Managers35. Snmp NMS Security Options 2 Configuring Snmp Traps and Trap Dial-Out36. Snmp Traps and Trap Dial-Out Options 1 36. Snmp Traps and Trap Dial-Out Options 2 Link see -38, Communication Port Options36. Snmp Traps and Trap Dial-Out Options 3 Link Traps Possible Settings Disable, Up, Down, BothEnterprise Specific Traps Dlci Traps on Interfaces Filter Selection Field Possible Settings Network, Ports, DBM, All, None36. Snmp Traps and Trap Dial-Out Options 4 Rmon TrapsTrap Dial-Out Dial-Out Delay TIme Min36. Snmp Traps and Trap Dial-Out Options 5 Trap DisconnectLatency Traps 36. Snmp Traps and Trap Dial-Out Options 6Alternate Dial-Out Directory IP SLV Availability TrapsConfiguring Ethernet Management 37. Ethernet Management Options 137. Ethernet Management Options 2 Proxy ARP38. Communication Port Options 1 Configuring the Communication PortCharacter Length Parity Login Required38. Communication Port Options 2 Stop Bits103 38. Communication Port Options 338. Communication Port Options 4 RIP38. Communication Port Options 5 Configuring the Modem Port39. Modem Port Options 1 106 39. Modem Port Options 2107 39. Modem Port Options 339. Modem Port Options 4 Main Menu→ Configuration→Auto Backup Criteria Configuring the Criteria for Automatic Backup40. Auto Backup Criteria Options 1 Backup Allowed Day From nnnn 40. Auto Backup Criteria Options 2When Auto Backup Allowed Backup Allowed Day To nnnnFeature-Specific Configuration Setting Up an External Modem AT Command String To configure the modem toMain Menu→Control→Modem Call Directories Setting Up an Internal ModemSetting Up Call Directories for Trap Dial-Out Valid characters include ForSetting Up to Use the Modem PassThru Feature Setting Up the DBM Physical Interface Setting Up Dial BackupMain Menu→Configuration→ISDN→Physical Setting Up Automatic Backup Configuration If you select ThenFollowing prompt When Appears If you select Connections? PVC Connections?Criteria for Automatic Backup in , Configuration Options For Originating a Backup Call For Answering a Backup Call Main Menu→Configuration→ISDN→Link ProfilesModifying Isdn Link Profiles Restricting Automatic Backup and Configuring Backup Timers Main Menu→Configuration→Auto-Backup CriteriaConfiguring the DBM Interface to Send Snmp Traps Assigning DLCIs to a Backup GroupChanging Operating Mode PVC Backup Over the Network InterfaceSetting Up Back-to-Back Operation Main Menu→Control→Change Operating ModeFeature-Specific Configuration 9000-A2-GB31-00 December Feature-Specific Configuration December ARP ATMRlsd DBMDTR RTSDSL DTEEIR IdslIsdn IP SLVHssi IN-5 IN-6 NMSPVC Snmp NMSIP Slip SLVIN-8 IN-9 IN-10
Related manuals
Manual 271 pages 14.3 Kb Manual 278 pages 35.32 Kb Manual 28 pages 41.96 Kb Manual 233 pages 22.17 Kb Manual 340 pages 17.41 Kb

and 9820-45M, 9123, 9623, 9783, 9720 specifications

The Paradyne 9820-8M, 9788, 9128 standalone, 9128 carrier-mount, and 9820-2M are critical components in telecommunications networks, designed to enhance data transmission and improve connectivity. Each model offers unique features and capabilities that cater to various requirements in both enterprise and service provider environments.

The Paradyne 9820-8M is a multi-service access platform that provides high-speed connectivity for voice, video, and data transmission. It supports multiple protocols, enabling seamless integration into existing infrastructures. Key features include a modular design that allows for scalability and easy upgrades, ensuring that organizations can adapt to evolving demands. Its advanced error correction and QoS (Quality of Service) features ensure reliable performance, even in challenging network conditions.

The Paradyne 9788 serves as a versatile platform for both digital and analog communications. It excels in the delivery of broadband services, supporting T1/E1 lines and providing robust mechanisms for data transmission. This model emphasizes redundancy and resilience, with built-in protection switching capabilities that maintain service continuity during faults or maintenance activities. Its compact design makes it an ideal solution for environments with space constraints.

The 9128 standalone model is aimed at customers requiring an easy-to-deploy solution for point-to-point connections. This model offers critical features such as an intuitive user interface, comprehensive diagnostics, and monitoring capabilities that facilitate system management. It also supports diverse network topologies, making it suitable for various deployment scenarios.

In contrast, the 9128 carrier-mount version is engineered for organizations needing to manage multiple connections within a central office or remote site. This model is specifically designed to be mounted in standard telecom racks, optimizing space utilization while maintaining high performance. Its robust hardware allows for excellent thermal management and environmental resilience.

Lastly, the Paradyne 9820-2M combines versatility with high-performance capabilities, making it a reliable choice for service providers. It features dual-channel support, enabling simultaneous transmission and providing a cost-effective solution for high-capacity data needs. With enhanced security features, including encryption capabilities, the 9820-2M ensures that sensitive information transmitted across networks is protected against unauthorized access.

Collectively, these Paradyne models exemplify advanced telecommunications technology, offering scalability, resilience, and high performance. Their diverse features cater to the unique demands of various users, from enterprise networks to service providers, facilitating the continual evolution of communication technologies.