Paradyne 9820-2M, and 9820-45M, 9820-8M, 9623, 9788, 9720, 9783 Monitor DSR, Monitor CTS, Monitor Rlsd

Page 61

3. Configuration Options

Table 3-13. Synchronous Network Data Port Physical Interface Options (2 of 2)

Monitor DSR

Possible Settings: Enable, Disable

Default Setting: Enable

Specifies whether the state of the DCE Ready (DSR) circuit on the network data port will be used to determine when valid data communication is possible with the unit. When this condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Display Conditions – This option does not appear when Port Type is set to X.21. The signal is assumed to be asserted.

Enable – Interchange circuit CC (ITU/CCITT 107) – DSR is monitored to determine when valid data is being sent from the DCE.

Disable – DSR is not monitored. DSR is assumed to be asserted and data is transmitted, regardless of the actual state of the lead.

Monitor CTS

Possible Settings: Enable, Disable

Default Setting: Enable

Specifies whether the state of the Clear to Send (CTS) circuit on the network data port will be used to determine when valid data communication is possible with the unit. When this condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Display Conditions – This option does not appear when Port Type is set to X.21. The signal is assumed to be asserted.

Enable – Interchange circuit CB (ITU/CCITT 106) – CTS is monitored to determine whether data should be transmitted to the DCE.

Disable – CTS is not monitored. CTS is assumed to be asserted and data is transmitted, regardless of the actual state of the lead.

Monitor RLSD

Possible Settings: Enable, Disable

Default Setting: Enable

Specifies whether the state of the Received Line Signal Detector (RLSD) circuit on the network data port will be used to determine when valid data communication is possible with the unit. When this condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

If Port Type is set to X.21, the Indication interchange circuit is monitored instead of RLSD.

Enable – Interchange circuit CF (ITU/CCITT 109) – RLSD is monitored to determine when valid data communication is possible with the DCE.

Disable – RLSD is not monitored. RLSD is assumed to be asserted and data is transmitted, regardless of the actual state of the lead.

9000-A2-GB31-00

December 2002

3-29

Image 61
Contents FrameSaver SLV Copyright 2002 Paradyne Corporation All rights reserved Contents Contents Index Feature-Specific ConfigurationContents December Document Organization Purpose and Intended AudienceSection Description Document Number Document Title Product-Related DocumentsFrameSaver SLV reference library contains Other FrameSaver model-specific documentation includesVii Conventions Used Convention Used When UsedConfiguration Procedures Configuration Menu Example Configuration MenuConfiguration Option Area Description Configuration Option AreasMain Menu→ Configuration Accessing and Displaying Configuration OptionsConfiguration→PVC Connections Changing Configuration OptionsSaving Configuration Options Basic Configuration Main Menu→ Easy Install Using the Easy Install FeatureEasy Install Screen Example DDS Interface Service Type Possible Settings Frame Relay, Leased Line, PPP Easy Install Configuration Options 1Dslam Easy Install Configuration Options 2Create a Dedicated Network Management Link Easy Install Configuration Options 3Ethernet Management Options Screen Time Slot Assignment Screen 9123, 9126Network 1 Line Framing Format 9123, 9126 Easy Install Configuration Options 4Network 1 Line Coding Format 9123, 9126 Network 1 Line Build Out 9520, 9520-ILMNetwork 1 DSL Line Rate Mode 9720, 9783 Easy Install Configuration Options 5DS0 Base Rate 9123, 9126 Network 1 Port Type 9820-2M, 9820-8MNetwork 1 DSL Line Rate Easy Install Configuration Options 6384 784Network 1 Channel Easy Install Configuration Options 7Configuration→Data Ports→DLCI Records Using RIP with FrameSaver SLV CSU/DSUsMain Menu→ Control→System Information Entering System Information and Setting the System ClockIf the selection is Enter Main Menu→ Auto-Configuration Setting Up Auto-ConfigurationMain Menu→ Auto-Configuration→Frame Relay Discovery Mode Selecting a Frame Relay Discovery ModeDiscovery Mode Configuration Description Takes place Automatically Removing a Circuit Configuration Option Tables Configuration OptionsConfiguration Options Configuring Frame Relay and LMI for the System CSU/DSUs Configuring the Overall SystemMain Menu→ Configuration→System →Frame Relay and LMI System Frame Relay and LMI Options 1System Frame Relay and LMI Options 2 System Frame Relay and LMI Options 3 LMI Heartbeat T1 Possible Settings 5, 10, 15, 20, 25 LMI Status Enquiry N1 Possible Settings 1, 2, 3, 4System Frame Relay and LMI Options 4 Main Menu→ Configuration→System→PPP Configuring PPP OptionsPossible Settings Independent, Port-1FollowsNet PPP OptionsField Setting After RfcCodePoints Selected Configuring Class of Service DefinitionsClass of Svc Name Class of Service DefinitionsMeasure Latency & Availability Code Points AssignedCode Point Definitions Code Point DefinitionsCode Pnt NameMain Menu→ Configuration→System→Service Level Verification Configuring Service Level Verification OptionsService Level Verification Options 1 SLV Type Available Settings Standard, COS 1-COSDlci Down on SLV Timeout Service Level Verification Options 2SLV Timeout Error Event Threshold SLV Timeout Clearing Event ThresholdSLV Latency Clearing Event Threshold Service Level Verification Options 3SLV Packet Size bytes Main Menu→ Configuration→System→General Configuring General System OptionsTest Timeout General System Options 1General System Options 2 General System Options 3 System Alarm RelayConfiguring the Network Interface Configuring Physical InterfacesMain Menu→ Configuration→Network→Physical T1 Network Physical Interface Options 1 T1 Network InterfaceTransmit Timing T1 Network Physical Interface Options 2Network Initiated LLB Network Initiated PLBT1 Network Physical Interface Options 3 Network Initiated Dclb Possible Settings Disable, V.54&ANSIAnsi Performance Report Messages ESFCircuit Identifier T1 Network Physical Interface Options 4T3 Network Physical Interface Options T3 Network InterfaceLine Build Out DDS Network Physical Interface Options 1 DDS Network InterfaceDSU Latching Loopback DDS Network Physical Interface Options 2Require DSU Latching Loopback Preamble Idsl Network Interface Operating Rate Possible Settings AutoRate, 64, 12810. Idsl Network Physical Interface Options ChannelSdsl Network Interface Line Rate Mode Possible Settings Hunt, AutoRate, Fixed11. Sdsl Network Physical Interface Options DSL Line Rate Kbps12. Shdsl Network Physical Interface Options 1 Shdsl Network Interface12. Shdsl Network Physical Interface Options 2 Synchronous Network InterfacePSD Mask Port TypeMonitor CTS Monitor DSRMonitor Rlsd 14. Hssi Network Data Port Physical Interface Options Hssi Network InterfaceMain Menu→ Configuration→Data Ports→Physical Configuring a User Data Port CSU/DSUsData Port Physical Interface 15. V.35 Data Port Physical Interface Options 115. V.35 Data Port Physical Interface Options 2 Port Use Possible Settings Frame Relay, Synchronous DataMax Port Rate Port Base RateTransmit Clock Source 15. V.35 Data Port Physical Interface Options 3Monitor RTS Monitor DTR 15. V.35 Data Port Physical Interface Options 4Port DTE Initiated Loopbacks 15. V.35 Data Port Physical Interface Options 5 Action on Network Yellow AlarmInvert Transmit and Receive Data 15. V.35 Data Port Physical Interface Options 6 EIA-530-A/X.21/V.35 Data Port Physical InterfaceTransmit Clock Source 17. Hssi Data Port Physical Interface Options 1 Hssi Data Port Physical Interface17. Hssi Data Port Physical Interface Options 2 17. Hssi Data Port Physical Interface Options 3 Main Menu→ Configuration→T3 User Ports→ Physical Configuring the T3 User Port 9520-ILM18. T3 User Port Physical Interface Options Main Menu→ Configuration→DSX-1 Configuring the DSX-1 Interface 912619. DSX-1 Physical Interface Options 1 Interface StatusSend All Ones on DSX-1 Failure 19. DSX-1 Physical Interface Options 2Main Menu→ Configuration→ISDN→Physical Configuring the Isdn DBM Interface 9126, 9128Service Profile ID Spid 1 or 20. Isdn BRI DBM Physical Interface Options 912621. Isdn PRI DBM Physical Interface Options 9128 1 Switch Type Possible Settings NI-2, ATT4ESS, ATT5ESSLocal Phone Number 21. Isdn PRI DBM Physical Interface Options 9128 2 Line Build Out LBO Possible Settings 0.0, -7.5, -1521. Isdn PRI DBM Physical Interface Options 9128 3 Main Menu→ Configuration→ISDN→ISDN Link Profiles Setting Up Isdn Link Profiles 9126, 912822. Isdn Link Profile Options 1 Link NameOutbound Phone Number 22. Isdn Link Profile Options 2Inbound Calling ID 1 or Maximum Link Rate Kbps22. Isdn Link Profile Options 3 Assigning Time Slots/Cross ConnectionsCaller Identification Method Alternate Outbound Phone NumberValue Meaning Assigning Time Slots to the Network InterfacePPP Assigning DSX-1 Time Slots to the Network Interface DSX-1 to Network Time Slot Assignment Screen Example DSX-1 Signaling Assignments and Trunk Conditioning RBS Idle PLAR3idle Synchronous Data Port Assignment Screen Example Clearing Assignments 24. Interface Frame Relay Options 1 Configuring Frame Relay for an InterfaceLMI Traffic Policing 24. Interface Frame Relay Options 2LMI Parameters Frame Relay DS0s Base Rate24. Interface Frame Relay Options 3 Main Menu→ Configuration→Network/Data Ports → PPP Configuring PPP for an Interface25. Interface PPP Options 26. Dlci Record Options 1 Manually Configuring Dlci RecordsDlci Number CIR bps 26. Dlci Record Options 2Committed Burst Size Bc Bits 26. Dlci Record Options 3Excess Burst Size Bits 26. Dlci Record Options 4 Backup Group Possible Settings A, B, C, . . . Z, NoneDlci Priority Outbound Management PriorityMain Menu →Configuration →Network →Circuit Records Configuring Circuit Records for the Network Interface27. Circuit Records Options 1 VPI,VCI Number9783 0 9788 0 27. Circuit Records Options 2Excess Burst Size Be Bits 27. Circuit Records Options 39783 9788 Main Menu→ Configuration→Network →ATM Configuring ATM for the Network InterfaceCell Delineation Error Event Threshold 28. Network ATM OptionsMain Menu→ Configuration→PVC Connections Configuring PVC Connections29. PVC Connection Options 1 Source DlciSource Edlci 29. PVC Connection Options 2Primary Destination Link Primary Destination DlciPrimary Destination Edlci 29. PVC Connection Options 3Alternate Destination Link Alternate Destination DlciAlternate Destination Edlci 29. PVC Connection Options 4Main Menu→ Configuration→IP Path List Static Configuring the IP Path List30. IP Path List Setting Up Management and Communication Options 31. Node IP Options 1 Configuring Node IP Information31. Node IP Options 2 31. Node IP Options 3 TS Access Management LinkManagement MTU Size TS Management Snmp Validation 31. Node IP Options 432. Management PVC Options 1 Configuring Management PVCsPayload Managed 32. Management PVC Options 2Set DE Primary Dlci 32. Management PVC Options 3Primary Edlci 32. Management PVC Options 4Alternate Dlci 32. Management PVC Options 5Alternate Edlci Encapsulation 32. Management PVC Options 6Name 1 Access Configuring General Snmp Management33. General Snmp Management Options 1 Snmp ManagementName 2 Access Configuring Telnet and/or FTP Session Support33. General Snmp Management Options 2 34. Telnet and FTP Session Options 1 Telnet Login RequiredTelnet Session 34. Telnet and FTP Session Options 2 35. Snmp NMS Security Options 1 Configuring Snmp NMS SecurityNMS IP Validation Number of Managers35. Snmp NMS Security Options 2 Configuring Snmp Traps and Trap Dial-Out36. Snmp Traps and Trap Dial-Out Options 1 Link see -38, Communication Port Options 36. Snmp Traps and Trap Dial-Out Options 236. Snmp Traps and Trap Dial-Out Options 3 Link Traps Possible Settings Disable, Up, Down, BothEnterprise Specific Traps 36. Snmp Traps and Trap Dial-Out Options 4 Possible Settings Network, Ports, DBM, All, NoneDlci Traps on Interfaces Filter Selection Field Rmon Traps36. Snmp Traps and Trap Dial-Out Options 5 Dial-Out Delay TIme MinTrap Dial-Out Trap DisconnectAlternate Dial-Out Directory 36. Snmp Traps and Trap Dial-Out Options 6Latency Traps IP SLV Availability Traps37. Ethernet Management Options 1 Configuring Ethernet ManagementProxy ARP 37. Ethernet Management Options 238. Communication Port Options 1 Configuring the Communication PortCharacter Length 38. Communication Port Options 2 Login RequiredParity Stop Bits38. Communication Port Options 3 103RIP 38. Communication Port Options 438. Communication Port Options 5 Configuring the Modem Port39. Modem Port Options 1 39. Modem Port Options 2 10639. Modem Port Options 3 10739. Modem Port Options 4 Main Menu→ Configuration→Auto Backup Criteria Configuring the Criteria for Automatic Backup40. Auto Backup Criteria Options 1 When Auto Backup Allowed 40. Auto Backup Criteria Options 2Backup Allowed Day From nnnn Backup Allowed Day To nnnnFeature-Specific Configuration AT Command String To configure the modem to Setting Up an External ModemSetting Up Call Directories for Trap Dial-Out Setting Up an Internal ModemMain Menu→Control→Modem Call Directories Valid characters include ForSetting Up to Use the Modem PassThru Feature Setting Up the DBM Physical Interface Setting Up Dial BackupMain Menu→Configuration→ISDN→Physical If you select Then Setting Up Automatic Backup ConfigurationConnections? PVC Connections? Following prompt When Appears If you selectCriteria for Automatic Backup in , Configuration Options For Originating a Backup Call For Answering a Backup Call Main Menu→Configuration→ISDN→Link ProfilesModifying Isdn Link Profiles Main Menu→Configuration→Auto-Backup Criteria Restricting Automatic Backup and Configuring Backup TimersAssigning DLCIs to a Backup Group Configuring the DBM Interface to Send Snmp TrapsSetting Up Back-to-Back Operation PVC Backup Over the Network InterfaceChanging Operating Mode Main Menu→Control→Change Operating ModeFeature-Specific Configuration 9000-A2-GB31-00 December Feature-Specific Configuration December ATM ARPDTR DBMRlsd RTSEIR DTEDSL IdslIsdn IP SLVHssi IN-5 NMS IN-6IP Slip Snmp NMSPVC SLVIN-8 IN-9 IN-10
Related manuals
Manual 271 pages 14.3 Kb Manual 278 pages 35.32 Kb Manual 28 pages 41.96 Kb Manual 233 pages 22.17 Kb Manual 340 pages 17.41 Kb

and 9820-45M, 9123, 9623, 9783, 9720 specifications

The Paradyne 9820-8M, 9788, 9128 standalone, 9128 carrier-mount, and 9820-2M are critical components in telecommunications networks, designed to enhance data transmission and improve connectivity. Each model offers unique features and capabilities that cater to various requirements in both enterprise and service provider environments.

The Paradyne 9820-8M is a multi-service access platform that provides high-speed connectivity for voice, video, and data transmission. It supports multiple protocols, enabling seamless integration into existing infrastructures. Key features include a modular design that allows for scalability and easy upgrades, ensuring that organizations can adapt to evolving demands. Its advanced error correction and QoS (Quality of Service) features ensure reliable performance, even in challenging network conditions.

The Paradyne 9788 serves as a versatile platform for both digital and analog communications. It excels in the delivery of broadband services, supporting T1/E1 lines and providing robust mechanisms for data transmission. This model emphasizes redundancy and resilience, with built-in protection switching capabilities that maintain service continuity during faults or maintenance activities. Its compact design makes it an ideal solution for environments with space constraints.

The 9128 standalone model is aimed at customers requiring an easy-to-deploy solution for point-to-point connections. This model offers critical features such as an intuitive user interface, comprehensive diagnostics, and monitoring capabilities that facilitate system management. It also supports diverse network topologies, making it suitable for various deployment scenarios.

In contrast, the 9128 carrier-mount version is engineered for organizations needing to manage multiple connections within a central office or remote site. This model is specifically designed to be mounted in standard telecom racks, optimizing space utilization while maintaining high performance. Its robust hardware allows for excellent thermal management and environmental resilience.

Lastly, the Paradyne 9820-2M combines versatility with high-performance capabilities, making it a reliable choice for service providers. It features dual-channel support, enabling simultaneous transmission and providing a cost-effective solution for high-capacity data needs. With enhanced security features, including encryption capabilities, the 9820-2M ensures that sensitive information transmitted across networks is protected against unauthorized access.

Collectively, these Paradyne models exemplify advanced telecommunications technology, offering scalability, resilience, and high performance. Their diverse features cater to the unique demands of various users, from enterprise networks to service providers, facilitating the continual evolution of communication technologies.