4. Addressing Ports

4.1 Setting the address

The base address of each port of the DS-200/300 is set using two DIP switch packs. When setting the address selection switches, a switch in the "ON" position specifies that the corresponding address line must be a logic 0 for the port to be selected. Similarly, a switch in the "OFF" position forces the corresponding address line to be a logic 1 for the port to be selected.

A full sixteen bit address decode is implemented to reduce the chance of address conflicts with other adapters in the system. Each serial port on the DS-200/300 uses 8 consecutive I/O locations. The two ports reside in their own independent block of I/O space in eight byte increments.

Switches SW1 and SW2 select address lines A15 through A3 for Serial 0 and switches SW3 and SW4 select address lines A15 through A3 for Serial 1. The remaining address lines (A2, A1 and A0) are used by the UART to select the register being accessed. The sixth position on SW2 is used to enable or disable Serial 0 and the sixth position on SW4 is used to enable or disable Serial 1.

Figure 5 shows how the switches on the DS-200/300 represent the address values for serial ports. This figure can be used to explain the examples shown in Figure 6.

A serial port's address is a 16-bit quantity that is most often expressed

in four hexadecimal (base 16) digits. A hex digit can hold a value from 0 to 15 (decimal), and is made up of four binary bits given weights of eight, four, two, and one, hence the maximum value of 8+4+2+1 = 15.

A possible serial port address is 5220 hex. The example below shows how the hex digits are broken down into binary bits.

Binary bits

0

1

0

1

0

0

1

0

0

0

1

0

0

0

0

0

Bit weight

8

4

2

1

8

4

2

1

8

4

2

1

8

4

2

1

Sum of bits

0+4+0+1

0+0+2+0

0+0+2+0

0+0+0+0

Hex digits

 

 

5

 

 

 

2

 

 

 

2

 

 

 

0

 

These address bits are set by the switches.

All other bits are considered to be zero.

0 1 0 1

0 0 1 0

0 0 1 0

0 0 0 0

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5 --- Examination of a serial port base address

 

 

 

 

DS-200/300 User's Manual

 

 

4-1

Image 16
Contents DS-200/300 Page Warranty Information DS-200/300Quatech Inc Iii Table of Contents General Information This Page Intentionally Left Blank Installation Photo of DS-200/300 Quatech Inc Windows 95 Configuration Using the Add New Hardware WizardQuatech Inc Viewing and Changing Resources with Device Manager Page Page Setting the address Addressing PortsSerial 0 uses SW1 and SW2 Serial 1 uses SW3 and SW4 Enabling or disabling ports Recommended addresses for serial portsData Rate Multiplier Jumper Block Data Rate MultiplierOptions Register Options Register bit definitions This Page Intentionally Left Blank Interrupt Level IRQ Interrupt level IRQ selection Quatech IncInterrupt Sharing Interrupt Status Register contents Quatech Inc Interrupt Status RegisterThis Page Intentionally Left Blank Output Configuration Jumper/Channel/Function correspondenceRclk RTS/CTS handshakeXclk AUXIN/AUXOUT Loopback Xclk selection on J5, J7Half Duplex/Full Duplex selection J6/J8 J6 = Serial0 J8 = Serial1Factory Default Configuration of DS-200/300 Output control block diagramTermination Resistors RS-422/485 Peripheral ConnectionDS-200/300 connector definitions for RS-422/485 This Page Intentionally Left Blank Specifications Baud RatesQuatech Inc Troubleshooting Computer will not boot upPage DS-200/300 Revision March