Quatech DS-200/300 user manual Enabling or disabling ports, Recommended addresses for serial ports

Page 18

The standard addresses for serial ports COM1 and COM2 are listed in Figure 7. Recommended addresses for serial ports COM3 and COM4 are also listed. The switch settings for these addresses are shown in Figure 6.

PORT

TYPICAL I/O ADDRESS

NOTES

 

 

 

COM1

03F8 hex

Factory default for Serial 0.

 

 

 

COM2

02F8 hex

Factory default for Serial 1.

 

 

 

COM3

03E8 hex

Recommendations only. No official standards

 

 

exist for COM3 and COM4.

COM4

02E8 hex

 

 

 

 

Figure 7 --- Recommended addresses for serial ports

4.2 Enabling or disabling ports

Each port of the DS-200/300 may be individually enabled or disabled. To enable a port, move the appropriate switch to the "ON" position. To disable a port, move the switch to the "OFF" position. This is illustrated in Figure 8 below.

The factory default configuration is both serial ports enabled.

Enabled

 

Disabled

Serial 1 uses SW2

 

Serial 2 uses SW4

 

 

 

 

 

 

SW2 or SW4

ON

SW2 or SW4

ON

1

2

3

4

5

6

1

2

3

4

5

6

Disabled

Enabled

 

(default)

 

 

 

 

Figure 8 --- Enabling and disabling ports

DS-200/300 User's Manual

4-3

Image 18
Contents DS-200/300 Page Warranty Information DS-200/300Quatech Inc Iii Table of Contents General Information This Page Intentionally Left Blank Installation Photo of DS-200/300 Quatech Inc Windows 95 Configuration Using the Add New Hardware WizardQuatech Inc Viewing and Changing Resources with Device Manager Page Page Setting the address Addressing PortsSerial 0 uses SW1 and SW2 Serial 1 uses SW3 and SW4 Enabling or disabling ports Recommended addresses for serial portsData Rate Multiplier Data Rate Multiplier Jumper BlockOptions Register Options Register bit definitions This Page Intentionally Left Blank Interrupt Level IRQ Interrupt level IRQ selection Quatech IncInterrupt Sharing Interrupt Status Register contents Quatech Inc Interrupt Status RegisterThis Page Intentionally Left Blank Output Configuration Jumper/Channel/Function correspondenceRTS/CTS handshake RclkXclk AUXIN/AUXOUT Loopback Xclk selection on J5, J7Half Duplex/Full Duplex selection J6/J8 J6 = Serial0 J8 = Serial1Factory Default Configuration of DS-200/300 Output control block diagramTermination Resistors RS-422/485 Peripheral ConnectionDS-200/300 connector definitions for RS-422/485 This Page Intentionally Left Blank Specifications Baud RatesQuatech Inc Troubleshooting Computer will not boot upPage DS-200/300 Revision March