Quatech DS-200/300 user manual Troubleshooting, Computer will not boot up

Page 36

9. Troubleshooting

Listed here are some common problems and frequent causes of those problems. Suggestions for corrective action are given. If the information here does not provide a solution, contact Quatech Customer Service for technical support.

Any unauthorized repairs or modifications will void the DS-200/300's warranty.

Computer will not boot up.

1.Is the DS-200/300 properly inserted? Remove the card and try again. Perhaps try a different expansion slot.

2.Is the base address correctly set? Check for address conflicts with other devices in the system. Remember that each port on the DS-200/300 requires 8 bytes of I/O space. Set a different address if necessary.

3.The DS-200/300 may be defective. Contact Quatech Customer Service for instructions.

Cannot communicate with other equipment.

1.Are the cable connections correct? Are the cables securely attached?

2.Are the base address and interrupt level (IRQ) correctly set? Check for address and IRQ conflicts with other devices in the system. Change the settings if necessary.

3.If you are trying to communicate with a DTE, a null-modem cable may be required.

4.If possible, use a loopback connector to test the port. This loopback needs to connect the following signals on a D-9 connector:

TxD+ and RxD+ (pins 2 and 4)

TxD- and RxD- (pins 7 and 8)

AUXOUT+ and AUXIN+ (pins 1 and 5)

AUXOUT- and AUXIN- (pins 6 and 9)

Sample Code and a detailed description of the DS-200/300's UARTs is available on Quatech's BBS (330)434-2481.

9-1

Quatech Inc.

Image 36
Contents DS-200/300 Page Warranty Information DS-200/300Quatech Inc Iii Table of Contents General Information This Page Intentionally Left Blank Installation Photo of DS-200/300 Quatech Inc Windows 95 Configuration Using the Add New Hardware WizardQuatech Inc Viewing and Changing Resources with Device Manager Page Page Setting the address Addressing PortsSerial 0 uses SW1 and SW2 Serial 1 uses SW3 and SW4 Enabling or disabling ports Recommended addresses for serial portsData Rate Multiplier Data Rate Multiplier Jumper BlockOptions Register Options Register bit definitions This Page Intentionally Left Blank Interrupt Level IRQ Interrupt level IRQ selection Quatech IncInterrupt Sharing Interrupt Status Register contents Quatech Inc Interrupt Status RegisterThis Page Intentionally Left Blank Output Configuration Jumper/Channel/Function correspondenceRTS/CTS handshake RclkXclk AUXIN/AUXOUT Loopback Xclk selection on J5, J7Half Duplex/Full Duplex selection J6/J8 J6 = Serial0 J8 = Serial1Factory Default Configuration of DS-200/300 Output control block diagramTermination Resistors RS-422/485 Peripheral ConnectionDS-200/300 connector definitions for RS-422/485 This Page Intentionally Left Blank Specifications Baud RatesQuatech Inc Troubleshooting Computer will not boot upPage DS-200/300 Revision March