Quatech DS-100 user manual Troubleshooting, Computer will not boot up

Page 41

9. Troubleshooting

Listed here are some common problems and frequent causes of those problems. Suggestions for corrective action are given. If the information here does not provide a solution, contact Quatech Customer Service for technical support.

Any unauthorized repairs or modifications will void the DS-100's warranty.

Computer will not boot up.

1.Is the DS-100 properly inserted? Remove the card and try again. Perhaps try a different expansion slot.

2.Is the base address correctly set? Check for address conflicts with other devices in the system. Remember that each port on the DS-100 requires 8 bytes of I/O space. Set a different address if necessary.

3.The DS-100 may be defective. Contact Quatech Customer Service for instructions.

Cannot communicate with other equipment.

1.Are the cable connections correct? Are the cables securely attached?

2.Are the base address and interrupt level (IRQ) correctly set? Check for address and IRQ conflicts with other devices in the system. Change the settings if necessary.

3.If you are trying to communicate with a DTE, a null-modem cable may be required.

4.If possible, use a loopback connector to test the port. This connector needs to connect the following sets of signals on a D-25 connector:

TxD and RxD (pins 2 and 3)

RTS and CTS (pins 4 and 5)

DCD, DTR, DSR, and RI (pins 8, 20, 6 and 22)

Sample Code and a detailed description of the DS-100's UARTs is available on Quatech's BBS (330)434-2481.

DS-100 User’s Manual

8-1

Image 41
Contents DS-100 Warranty Information Quatech Inc Declaration of Conformity Table of Contents General Information This Page Intentionally Left Blank Port Address IRQ Enabled InstallationDiagram of DS-100 Quatech Inc Using the Add New Hardware Wizard Windows 2000 ConfigurationDouble click on the Add New Hardware icon Quatech Inc Page Quatech Inc Quatech Inc Quatech Inc Next select Ports COM & LPT, click Next Quatech Inc Page Page Page Page Page Page Page Windows 95 Configuration Page Viewing and Changing Resources with Device Manager Windows 95 Device Manager Quatech Inc Page This Page Intentionally Left Blank Addressing Ports Setting the addressSerial 0 uses SW1 and SW2 Serial 1 uses SW3 and SW4 Enabling or disabling ports Interrupt level IRQ selection Quatech Inc Interrupt Level IRQInterrupt Sharing External Connections J5 -- Serial J6 -- Serial DS-100 connector definitions for EIA/TIA-232-E This Page Intentionally Left Blank Baud Rates SpecificationsTemperature Computer will not boot up TroubleshootingDS-100 Revision March