Patton electronic 1082/I user manual Configuring DIP Switch S1

Page 12

S1 S2

 

S2

ON

ON

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

S1

 

Switch toggle

S1

ON

 

 

 

 

 

 

7

8

 

 

 

 

 

6

 

 

 

 

 

5

 

 

 

 

 

4

 

 

 

 

 

3

 

 

 

 

 

2

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Push toggle up for ON position

Push toggle down for OFF position

ON

1 2 3 4 5 6 7 8

S1

ON

1 2

Figure 5. DIP switches S2 and S2

Figure 5 shows the orientation of the DIP switches in the “ON” and “OFF” positions.

Configuring DIP Switch S1

DIP switch S1 is where you configure the data rate, asynchronous or synchronous data format, transmit clock source, and response to RDL request. The following table summarizes default positions of DIP switches S1-1 through S1-8. Detailed descriptions of each switch follow the table.

S1 Summary Table

 

Position

Function

Factory Default

 

 

 

 

 

 

 

S1-1

Data Rate

On

}

64K Sync

 

S1-2

Data Rate

Off

 

 

 

 

 

 

 

S1-3

Reserved

On

 

 

 

 

 

 

 

 

 

S1-4

Reserved

On

 

 

 

S1-5

Async/Sync Data Format

Off

 

Async/Sync

 

 

 

 

 

 

 

S1-6

Tx Clock Source

On

}

Internal Clock

 

S1-7

Tx Clock Source

On

 

 

 

 

 

 

 

S1-8

Response to RDL Request

On

 

Enable

 

 

 

 

 

 

12

Image 12
Contents User Manual Table of Contents Model 1082/I Factory Replacement Parts Accessories Warranty Information FCC InformationCE Notice Service Tel 301 Mailsupport@patton.comFeatures General Information1082 Snmp Management Solutions DescriptionHTTP/HTML Management PPP Operational Background Applications Ethernet LAN Page Configuration Configuring the Hardware DIP SwitchesConfiguring DIP Switch S1 S1 Summary Table Position Function Factory DefaultSwitches S1-1 and S1-2 Data Rate S1-3 Setting S1-4Switch S1-5 Asynchronous/Sync Operation S1-5 SettingSwitches S1-6 and S1-7 System Clock Mode S1-6 S1-7 Clock Mode DescriptionSwitch S1-8 Response to RDL Request S1-8 SettingConfiguring DIP switch S2 S2 Summary Table Position Function Factory DefaultS2-1 Activation Description Switch S2-2 Front Panel Switch Disable S2-2 SettingSwitches S2-3, S2-6, S2-7 and S2-8 Reserved Installation Connecting DSL InterfaceConnecting 10BASE-T Ethernet Port to PC DTE Connecting 10BASE-T Ethernet Port to HUB DCE10Base-T DTE RJ-45 Pin NoPower Connection Universal AC Power 100-240VACDC Power To Power Supply JackTo -48VDC VinSourcePOWER-UP OperationLED Status Monitors LED Test Modes Remote Digital Loopback RDL/V.52 BERPage Diagnostics LED Status IndicatorsConnectors PowerTemperature Range DimensionsWeight AltitudeAppendix B Model # Description