Patton electronic 1082/I user manual Configuring DIP switch S2, S2-1 Activation Description

Page 15

Configuring DIP switch “S2”

Use the eight DIP switches in S2 to enable 19.2 kbps or 144* kbps syn- chronous operation and set the loopback modes. The following table summarizes default positions of DIP switches S2-1 through S2-8. Detailed descriptions of each switch follow the table.

S2 Summary Table

Position

Function

Factory Default

 

 

 

S2-1

19.2 or 144* kbps Enable

Off

 

 

 

S2-2

Front Panel Switch Disabl e

Off

 

 

 

S2-3

Reserved

Off

 

 

 

S2-4

Reserved

Off

 

 

 

S2-5

Reserved

Off

 

 

 

S2-6

Reserved

On

 

 

 

S2-7

Reserved

Off

 

 

 

S2-8

Reserved

Off

 

 

 

Switches S2-1: 19.2 kbps or 144* kbps Synchronous Rate Enable

Use switch S2-1 to allow the Model 1082/I and Model 1082/144/I to oper- ate at the 19.2 kbps synchronous data rate, or to enable the Model 1082/ 144/I to operate at the 144* kbps synchronous data rate.

S2-1

Activation

Description

 

 

 

Off

Disabled

Synchronous data rate is 32–128 kbps as

 

 

defined by switches S1-1 and S1-2

 

 

 

On

Enabled

Model 1082/I operates at synchronous 19.2 kbps

 

 

data rate (see note). The Model 1082/144/I oper-

 

 

ates at 144 kbps synchronous data rate (see note)

 

 

 

Note To operate at 19.2 kbps or 144 kbps, set switches S1-1 and S1-2 to the OFF position and switch S2-1 to ON (see section “Configur- ing DIP Switch S1” on page 12).

*144 kbps data rate is only available on the Model 1082/144/I.

19.2 kbps rate is available on all Model 1082 series modems except for the 1082/144/I.

15

Image 15
Contents User Manual Table of Contents Model 1082/I Factory Replacement Parts Accessories Warranty Information FCC InformationCE Notice Tel 301 Mailsupport@patton.com ServiceGeneral Information Features1082 Snmp Management Solutions DescriptionHTTP/HTML Management Applications PPP Operational BackgroundEthernet LAN Page Configuring the Hardware DIP Switches Configuration S1 Summary Table Position Function Factory Default Configuring DIP Switch S1S1-5 Setting Switches S1-1 and S1-2 Data RateS1-3 Setting S1-4 Switch S1-5 Asynchronous/Sync OperationS1-8 Setting Switches S1-6 and S1-7 System Clock ModeS1-6 S1-7 Clock Mode Description Switch S1-8 Response to RDL RequestConfiguring DIP switch S2 S2 Summary Table Position Function Factory DefaultS2-1 Activation Description Switch S2-2 Front Panel Switch Disable S2-2 SettingSwitches S2-3, S2-6, S2-7 and S2-8 Reserved Connecting DSL Interface InstallationRJ-45 Pin No Connecting 10BASE-T Ethernet Port to PC DTEConnecting 10BASE-T Ethernet Port to HUB DCE 10Base-T DTEUniversal AC Power 100-240VAC Power ConnectionTo Power Supply JackTo -48VDC VinSource DC PowerPOWER-UP OperationLED Status Monitors LED Remote Digital Loopback RDL/V.52 BER Test ModesPage Power DiagnosticsLED Status Indicators ConnectorsAltitude Temperature RangeDimensions WeightModel # Description Appendix B