Do not send a 511 test pattern from the test equipment when you connect external test equipment to the 1082.

Important

Activating RDL can be done in two ways:

1.Move the front panel toggle switch to appropriate position.

2.Set remote loopback from SNMP screen (when used with 1092ARC Rack Card)

Note Remote loopback cannot be activated until approximately 45 seconds after the two modems have linked to each other.

Note The Remote Digital Loopback (RDL) will not work for 144 kbps. You must first set the units to 128 kbps or slower to use the RDL.

To use the V.52 BER tests with the Remote Digital Loopback tests, do the following:

1.Locate the 511/RDL toggle switch on the front panel of the 1082/I and move it DOWN. This initiates the RDL and sends a 511 pattern into the loop. If any errors are present, the local modem’s red “ER” LED will blink continually.

2.If the above test indicates no errors are present, move the V.52 tog- gle switch UP, activating the 511E/RDL test with errors present. If the test is working properly, the local modem's red “ER” LED will blink approximately once per second. A successful 511E/RDL test will confirm that the link is in place, and that the Model 1082’s built-in “511” generator and detector are working properly.

24

Image 24
Contents User Manual Table of Contents Model 1082/I Factory Replacement Parts Accessories Warranty Information FCC InformationCE Notice Service Tel 301 Mailsupport@patton.comFeatures General Information1082 Snmp Management Solutions DescriptionHTTP/HTML Management PPP Operational Background ApplicationsEthernet LAN Page Configuration Configuring the Hardware DIP SwitchesConfiguring DIP Switch S1 S1 Summary Table Position Function Factory DefaultSwitches S1-1 and S1-2 Data Rate S1-3 Setting S1-4Switch S1-5 Asynchronous/Sync Operation S1-5 SettingSwitches S1-6 and S1-7 System Clock Mode S1-6 S1-7 Clock Mode DescriptionSwitch S1-8 Response to RDL Request S1-8 SettingConfiguring DIP switch S2 S2 Summary Table Position Function Factory DefaultS2-1 Activation Description Switch S2-2 Front Panel Switch Disable S2-2 SettingSwitches S2-3, S2-6, S2-7 and S2-8 Reserved Installation Connecting DSL InterfaceConnecting 10BASE-T Ethernet Port to PC DTE Connecting 10BASE-T Ethernet Port to HUB DCE10Base-T DTE RJ-45 Pin NoPower Connection Universal AC Power 100-240VACDC Power To Power Supply JackTo -48VDC VinSource POWER-UP Operation LED Status Monitors LED Test Modes Remote Digital Loopback RDL/V.52 BERPage Diagnostics LED Status IndicatorsConnectors PowerTemperature Range DimensionsWeight AltitudeAppendix B Model # Description