Patton electronic 1082/I user manual Led

Page 22

 

Table 1: LED status monitor indications

 

 

LED

Description

 

 

DSL Link

(Active Green) Solid green (On) indicates that the end to

 

end DSL Framer Link is up, signifying that the link across

 

the DSL span is active. The DSL Link LED is Off when the

 

link is down.

 

 

Status

Blinks yellow from one to eleven times to indicate system

 

status. Each pulse pattern is separated by a 2 second “off”

 

period. Greater pulse patterns have higher priority (buffer

 

saturation has greater priority than an empty MAC table).

 

Valid system statuses are:

 

1 pulse—system status is okay

 

2 pulses—no MAC entries in the MAC Address Table

 

3 pulses—Clear to Send (CTS) or Carrier Detect (DCD)

 

from base unit are not asserted

 

4 pulses—IM1/I buffer is saturated

 

5 pulses—WAN receive frame(s) too large

 

6 pulses—WAN receive frame(s) not octet aligned

 

7 pulses—WAN receive frame(s) aborted

 

8 pulses—Detected WAN receive frame(s) with CRC

 

9 pulses—Detected LAN receive frame(s) too large

 

10 pulses—Detected LAN receive frame(s) not octet

 

aligned

 

11 pulses—Detected LAN receive frame(s) with bad

 

CRC

 

 

10BT Link

(Active green) Solid green indicates that the 10Base-T

 

Ethernet interface has detected a valid SQE heartbeat, signi-

 

fying a valid 10Base-T connection

 

 

NS

(Active red) Solid red indicates that the Digital Signal Proces-

 

sors (DSPs) are not linked

 

 

ER

(Active red) Flashing red indicates CRC errors on DSL

 

(framer) side if DSL Link is active or if bit errors are received

 

during loop/BER test

 

ER flashes once, to indicate a CRC error (during normal

 

operation) or bit errors (during Remote Loopback 511/511E

 

tests)

 

 

TM

(Active yellow) Solid yellow indicates an Active Test Mode.

 

The unit may be placed in test mode by the local user or by

 

the remote user.

 

 

22

Image 22
Contents User Manual Table of Contents Model 1082/I Factory Replacement Parts Accessories FCC Information Warranty InformationCE Notice Service Tel 301 Mailsupport@patton.comFeatures General InformationDescription 1082 Snmp Management SolutionsHTTP/HTML Management PPP Operational Background ApplicationsEthernet LAN Page Configuration Configuring the Hardware DIP SwitchesConfiguring DIP Switch S1 S1 Summary Table Position Function Factory DefaultSwitch S1-5 Asynchronous/Sync Operation Switches S1-1 and S1-2 Data RateS1-3 Setting S1-4 S1-5 SettingSwitch S1-8 Response to RDL Request Switches S1-6 and S1-7 System Clock ModeS1-6 S1-7 Clock Mode Description S1-8 SettingS2 Summary Table Position Function Factory Default Configuring DIP switch S2S2-1 Activation Description S2-2 Setting Switch S2-2 Front Panel Switch DisableSwitches S2-3, S2-6, S2-7 and S2-8 Reserved Installation Connecting DSL Interface10Base-T DTE Connecting 10BASE-T Ethernet Port to PC DTEConnecting 10BASE-T Ethernet Port to HUB DCE RJ-45 Pin No Power Connection Universal AC Power 100-240VACDC Power To Power Supply JackTo -48VDC VinSourceOperation POWER-UPLED Status Monitors LED Test Modes Remote Digital Loopback RDL/V.52 BERPage Connectors DiagnosticsLED Status Indicators PowerWeight Temperature RangeDimensions AltitudeAppendix B Model # Description