Patton electronic 1094A user manual After the 511/511E pattern times out, the ER led

Page 12

Local Loop

After the 511/511E pattern times out, the ER led

with 511/511E

will begin flashing. It will remain this way until

(continued)

the pattern generator switch is turned off. Note

 

that the data at the local DTE and the remote

 

DTE are not valid. Because the data is

 

unframed there is no way for the framer to send

 

this data out to the DTE. This is an important

 

distinction because other Patton units will send

 

out the 511 pattern.

 

When the unit is placed into a Mode 2 Local

 

Loop, the 511/511E pattern generator on the

 

local unit is unavailable for transmission. As can

 

be seen from Figure 10, the 511/511E pattern

 

generator has no data path connections avail-

 

able. The 511/511E pattern generator is still

 

available on the remote unit. For more informa-

 

tion on the proper operation of this pattern gen-

 

erator please refer to the "Remote Digital Loop

 

with 511/511E" section.

Remote Digital The Remote Loop uses the EOC channel (an

Loopout-of-band signaling channel) to establish the remote link. Upon the RDL switch being thrown or DTE initiation, a RDL_ON Request signal is sent to the remote unit. The Remote unit then responds with an RDL Acknowledge command and the link is established. Data originates at the local DTE and is looped at the Remote PROCESSOR back to the Local DTE. Note that the data is also passed through to the Remote DTE and is not squelched. When a Remote unit enters RDL, it changes its' Restart timeout to one minute (the reason will be explain in the RDL with 511/511E section). If the line is discon- nected, the local unit will Restart (NS led activat- ed) after 4 - 6 seconds, but the Remote unit will wait for one minute before it Restarts. Note that the transmit data at the Remote DTE is ignored. When the switch is thrown or the DTE removes the RDL request, the local unit will transmit an RDL_OFF Request to the Remote unit. The

Framer

Pattern

Loop

Line

Gen/Det

Control

 

Processor

 

Loop Pattern

Control Gen/Det

Processor

Framer

local unit will keep its' TM led active until this request has been completely sent out. If the switch is thrown again before the completion of the termination phase the switch will be ignored until it is placed back into the normal position.

Figure 9. Block Diagram Local Loop Mode 1 with 511/511E

Framer

Pattern

Loop

Line

Loop

Pattern

Framer

 

Gen/Det

Control

Control

Gen/Det

 

 

 

 

 

Processor

 

Processor

 

 

Figure 10. Block Diagram Local Loop Mode 2 with 511/511E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pattern

 

Loop

 

 

 

Loop

 

 

 

Pattern

 

 

 

 

 

 

Framer

 

 

 

 

 

 

 

 

 

Framer

 

 

 

 

 

Line

 

 

 

 

 

 

 

 

 

Gen/Det

 

Control

 

 

Control

 

 

 

Gen/Det

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

 

 

 

 

Processor

 

 

 

 

 

Figure 11. Block Diagram Remote Loop

21

22

Image 12
Contents User NUA L Section Radio and TV InterferenceCE Notice Service FeaturesTel Email support@patton.com DescriptionConfiguring the Hardware DIP Switches Configuration DIP Switch Set S1 Reserved SwitchesConfiguration DIP Switch Set S2 S2 Summary TableCO/CP S3 Summary TableSwitch S3-7 Reset Software Defaults Switch S3-8 Transmit Data TD Sampling PointConnecting the Twisted Pair Interface Connecting the Serial Port Configuring the X.21 QuikConnect Module Connecting PowerConnecting to a DC Power Source POWER-UP LED Status MonitorsTD & RD CTSSymbol Indicators FramerPattern Gen/Det Loop ControlLoops and Patterns Local Loop There are two different modes of operation for aLocal Loop With 511/511EAfter the 511/511E pattern times out, the ER led Remote Digital Loop with511/511E Patton Electronics Model 1094A Specifications Patton Electronics Model # Description Patton Electronics Model 1094A Interface PIN AssignmentsDTE /DCE Configuration Pin # SignalPatton Electronics Model 1094A Transmission Distances Transmission Distance Patton NetLink Hdsl Model 1094A