3.0 CONFIGURATION

The Model 1094A is equipped with three sets of eight DIP switch- es, which allow configuration of the unit for a wide variety of applica- tions. This section describes switch locations and explains all possible configurations.

3.1 CONFIGURING THE HARDWARE DIP SWITCHES

The 24 external switches are grouped into three eight-switch sets, and are externally accessible from the underside of the Model 1094A (See Figure 1).

On

S3

BackS2Front

3.1.1 Configuration DIP Switch Set “S1” - Reserved Switches

All Switches in Switch S1 are reserved for future use. These switches should remain in the On position.

3.1.2 Configuration DIP Switch Set “S2”

The configuration switches on S2 allow you to specify the Clocking Mode and response to DTE Loop Enable. Default settings of S2 are shown in the table below.

S2 SUMMARY TABLE

Position

Function

Factory Default

S2-1

Reserved

Off

S2-2

Reserved

Off

S2-3

Reserved

Off

S2-4

Reserved

Off

S2-5

Reserved

Off

Off

S1

S2-6

Clock Mode

On

Receive

S2-7

Clock Mode

Off

Recovered Clock

S2-8

Enable Loop from DTE Off

Disable

Switch S2-1, S2-2, S2-3, S2-4, and S-5: Reserved for Future Use and Should Remain in the Off Position.

Figure 1. Underside of Model 1094A, Showing Location of DIP Switches

The three sets of DIP switches on the underside of the Model 1094A will be referred to as S1, S2, and S3. As Figure 2 shows, the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions.

ON ON

1

2

3

4

5

6

7

8

OFF

Figure 2. Close Up of Configuration Switches (all sets are identical in appearance)

5

6

Image 4
Contents User NUA L Radio and TV Interference SectionCE Notice Service FeaturesTel Email support@patton.com DescriptionConfiguring the Hardware DIP Switches Configuration DIP Switch Set S1 Reserved SwitchesConfiguration DIP Switch Set S2 S2 Summary TableCO/CP S3 Summary TableSwitch S3-8 Transmit Data TD Sampling Point Switch S3-7 Reset Software DefaultsConnecting the Twisted Pair Interface Connecting the Serial Port Connecting Power Configuring the X.21 QuikConnect ModuleConnecting to a DC Power Source POWER-UP LED Status MonitorsTD & RD CTSSymbol Indicators FramerPattern Gen/Det Loop ControlLoops and Patterns Local Loop There are two different modes of operation for aLocal Loop With 511/511EAfter the 511/511E pattern times out, the ER led Loop with Remote Digital511/511E Patton Electronics Model 1094A Specifications Patton Electronics Model # Description Patton Electronics Model 1094A Interface PIN AssignmentsDTE /DCE Configuration Pin # SignalPatton Electronics Model 1094A Transmission Distances Transmission Distance Patton NetLink Hdsl Model 1094A