4.2.4 Configuring the X.21 QuikConnect™ Module

The serial port on the X.21 QuikConnect™ Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below:

To reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.2.1. The DCE/DTE strap is located on the bottom side of the module’s PC board. The arrows on the top of the strap indicate the configuration of the X.21 port (for example, if the DCE arrows are pointing toward the DB-15 connector, the X.21 port is wired as a DCE). Reverse the DCE/DTE orientation by pulling the strap out of its socket, rotating it 180º, then plugging the strap back into the socket. You will see that the DCE/DTE arrows now point in the opposite directions, showing the new configuration of the X.21 port. Reinstall the module according to the instructions in Section 4.2.1.

4.3 CONNECTING POWER

The Model 1094A is available with two power supply options:

Universal Interface AC Power Supply option (Model 1094A-UI) operates in environments ranging from 100 to 253 VAC, with no re- configuration necessary (see Appendix B for available domestic and international power cords).

DC Power Supply option (Model 1094A-DC) operates in 48 VDC environments and is equipped with a 3-pin “terminal strip” style con- nector.

4.3.1 Connecting to an AC Power Source

The Universal Interface AC Supply is equipped with a male IEC- 320 power connection. A domestic (US) power supply cord is sup- plied with the unit at no extra charge. To connect the standard or uni- versal power supply, follow these steps:

1)Attach the power cord (supplied) to the shrouded male IEC- 320 connector on the rear of the Model 1094A.

2)Plug the power cord into a nearby AC power outlet.

3)Turn the rear power switch ON.

4.3.2 Connecting to a DC Power Source

The 48 VDC power supply option uses a 3-pin terminal block with spring-type connectors. Please refer to the Model 1090 Series Service Manual for the power line voltage connections.

WARNING! There are no user-serviceable parts in the power supply section of the Model 1094A. Fuse replacement should only be performed by qualified service personnel. Contact Patton Electronics Technical support at (301) 975-1007, via our web site at http://www.patton.com, or by e-mail at support@pat- ton.com, for more information.

13

14

Image 8
Contents User NUA L CE Notice SectionRadio and TV Interference Service FeaturesTel Email support@patton.com DescriptionConfiguring the Hardware DIP Switches Configuration DIP Switch Set S1 Reserved SwitchesConfiguration DIP Switch Set S2 S2 Summary TableCO/CP S3 Summary TableConnecting the Twisted Pair Interface Switch S3-7 Reset Software DefaultsSwitch S3-8 Transmit Data TD Sampling Point Connecting the Serial Port Connecting to a DC Power Source Configuring the X.21 QuikConnect ModuleConnecting Power POWER-UP LED Status MonitorsTD & RD CTSSymbol Indicators FramerPattern Gen/Det Loop ControlLoops and Patterns Local Loop There are two different modes of operation for aLocal Loop With 511/511EAfter the 511/511E pattern times out, the ER led 511/511E Remote DigitalLoop with Patton Electronics Model 1094A Specifications Patton Electronics Model # Description Patton Electronics Model 1094A Interface PIN AssignmentsDTE /DCE Configuration Pin # SignalPatton Electronics Model 1094A Transmission Distances Transmission Distance Patton NetLink Hdsl Model 1094A